ap2000t208001cb

Drain coolant, pour in

Typ ap · téma 20.00 · verze 0100 · 2005-07-12

Platí pro: ENGINE 457.944 in MODEL NMB613.367

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 20 Chlazení motoru › 20.00 Všeobecné — Řada 613 (modely 367)

EinPAS 15 Motor › 15.25 Chladicí systém motoru › 15.25.5 Kompletní okruh chlazení — Řada 613 (modely 367)

Platí také pro motory/převodovky: 457 944

AP20.00-T-2080-01CB

Drain coolant, pour in

Danger!

Risk of injury to skin and eyes suffering scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles.

Wear protective gloves, protective clothing and eye protection.

AS20.00-Z-0001-01A

Engine cooling system

Number

Designation

Engine 402.970, 441.980, 446.938, 457.944

BF20.00-N-1001-01D

Coolant capacity

without VOITH retarder

Liters

75...100

with VOITH retarder

Liters

95...120

Specifications for Operating Fluids

Sheet

BB00.40-P-0310-01A

Sheet

BB00.40-P-0325-02A

Drain coolant, pour in

T83.70-0025-11

Drain coolant

When disposing of coolant, the legal requirements and local waste water regulations must be observed.

1 Disconnect electrical connector (arrow) of circulation pump (1).

Because of risk of damage, do not operate circulation pump without coolant.

2 Open shutoff valve of heater feed (2).

Drain coolant, pour in

T20.00-0031-11

3 Open shutoff valve of heater return flow (3).

Drain coolant, pour in
Drain coolant, pour in

T20.10-0023-01

4 Remove coolant hose (4) from connection (5) of water pump and drain coolant.

5 Unscrew screw (6) from coolant connection (7) at retarder and drain coolant, if necessary slacken hose clamps and detach coolant hose.

T20.20-0065-01

Pour in coolant

6 Clean drain openings which are plugged by deposits.

7 Screw in all drain plugs.

Inspect seals of the drain plugs, replace if necessary.

8 Prepare and pour in coolant of the specified composition.

9 Plug together electrical connection of circulation pump (1).

Odkazované dokumenty