AR42.60-L-0010A | Checking pressure governor | 6.7.09 |
MODEL 668, 670 with CODE (B16) Hydraulic 2-circuit / compressed air 2-circuit brakes
MODEL 668, 670
with CODE (B16) Hydraulic 2-circuit / compressed air 2-circuit brakes
with CODE (B43) 2-line trailer brake (EC)
MODEL 668, 670
with CODE (B16) Hydraulic 2-circuit / compressed air 2-circuit brakes
with CODE (B43) 2-line trailer brake (EC)
with CODE (CE2) Rear air suspension
with CODE (CE3) Front and rear air suspension
L42.60-0056-01
4.03 Four-circuit protection valve
6.13 Compressed air drier with integrated pressure regulator
L42.60-0059-01
L42.60-0057-01
H1 Test connection (circuit 1)
H2 Test connection (circuit 2)
H3 Test connection (air suspension system)
L42.60-0058-01
Modification notes
12.3.01 | Value changed from 10 (+0.2) bar to 10 (0.2) bar | Value in BE42.10-N-1001-10C changed for models 668, 670 with code B16 steel suspension |
| Checking | ||
| Notes on pressure vessel for ancillary consumers | ||
| Notes on four-circuit protection valve | ||
1.1 | Connect test kit to test connection (circuit 1) (H1) | Except front and rear air suspension, code CE3 Except rear air suspension CE2 | |
Between four-circuit protection valve (4.03) and compressed-air reservoir of front axle. | |||
| |||
1.2 | Connect test kit to test connection (air suspension system) (H3) | With front and rear air suspension, code CE3 With rear air suspension CE2 | |
Between the compressed air reservoir and safety valve of air suspension system. | |||
| |||
2 | Lower brake-air pressure | Lower the reservoir pressure below the cut-in pressure of the compressed air drier with integral pressure regulator (6.13). | |
| |||
3 | Fill the brake system with compressed air until the compressed air drier with integral pressure regulator (6.13) cuts out | The cutoff pressure must not exceed the specified value otherwise the safety valve in the supply reservoir may respond, preventing the pressure regulator from switching off properly. | |
| |||
If the measured cutoff pressure and specified pressure are different: | |||
Replace compressed air drier with integral pressure regulator (6.13). | |||
4 | Lower the reservoir pressure until the cut-in pressure of the compressed air drier with integral pressure regulator (6.13) is reached | Check cut-in pressure and compare with specified value. If it varies from the specified value: | |
Replace compressed air drier with integral pressure regulator (6.13). | |||
| |||
5 | Check switching span of compressed air drier with integral pressure regulator (6.13) between the cut-in pressure and cutoff pressure | The cutoff pressure must not exceed the specified value otherwise the safety valve may respond and the compressed air drier with integral pressure regulator (6.13) does not switch off properly. | |
| |||
6 | Check difference between cutoff and cut-in pressure | If it varies from the specified value: | |
Replace compressed air drier with integral pressure regulator (6.13). | |||
| |||
7.1 | Detach test kit from test connection (circuit 1) (H1) | Except front and rear air suspension, code CE3 Except rear air suspension CE2 | |
Between four-circuit protection valve (4.03) and compressed-air reservoir of front axle. | |||
| |||
7.2 | Detach test kit from test connection (air suspension system) (H3) | With front and rear air suspension, code CE3 With rear air suspension CE2 | |
Between the compressed air reservoir and safety valve of air suspension system. | |||
|
Test and adjustment values for service brake
Number | Designation | Model | Model | Model | |
BE42.10-N-1001-10C | Cut-off pressure | bar | 12,3 | 8.5 (-0.4) | 10,2 |
BE42.10-N-1005-10C | Pressure governor control range | bar | 1.0 (+0.5) | 0.6 (+0.4) | 0.7 (+0.5) |
BE42.10-N-1007-10C | Pressure regulator control range | bar | 12.3 to 10.2 | 8.5 to 7.1 | 10.2 to 8.6 |
BE42.10-N-1009-10C | Cut-in pressure | bar | 11.3 to 10.2 | 7.9 to 7.1 | 9.5 to 8.7 |
Test and adjustment values for service brake
Number | Designation | Model | Model | Model | |
BE42.10-N-1001-10C | Cut-off pressure | bar | 10 (0.2) | 10 (0.2) | 12,3 |
BE42.10-N-1005-10C | Pressure governor control range | bar | 0.7 (+0.5) | 0.7 (+0.5) | 1.0 (+0.5) |
BE42.10-N-1007-10C | Pressure regulator control range | bar | 10.2 to 8.6 | 10.2 to 8.6 | 12.3 to 10.2 |
BE42.10-N-1009-10C | Cut-in pressure | bar | 9.5 to 8.6 | 9.5 to 8.6 | 11.3 to 10.2 |
360 589 00 21 00
Test kit