AR83.30-P-5200FF | Remove/install AC housing | 11.5.06 |
MODEL 454.0 with ENGINE 134.9, 135.9, 639.9
with CODE (I01) Air conditioning Plus
with CODE (I77) Manual air conditioning
P83.30-3998-06
1 Refrigerant lines
2 Bolt
3 Yoke plate
4 Cover
5 Coolant hoses
6 Fitting
16 Expansion valve
17 Tie strap
P83.30-3990-08
Shown on model 454.03 with code (I01) Air conditioning Plus
7 Electrical wiring harnesses
8 Electrical connector
9 Electrical connector
13 Bracket
14 Electrical connector
15 Defroster vent
10 AC housing
11 Air recirculation box
12 Electrical connector
| Remove/install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Conduct if air conditioning system is damaged or leaking | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling refrigerant R134a | ||
1 | Discharge air conditioning system | Installation: Evacuate air conditioning and then fill. | |
2.1 | Remove water collector | Engine 639.9: | |
3 | Remove screw (2) and remove yoke plate (3) with cover (4) | | |
4 | Pull refrigerant lines (1) out of expansion valve (16) | Use suitable plugs to seal openings on refrigerant lines (1) and on the expansion valve (16). | |
Installation: Replace sealing rings at refrigerant lines (1) and coat with compressor fluid when inserting. | |||
5 | Drain coolant | Engines 134.9, 135.9 | |
Engine 639.9 | |||
6 | Remove coolant hoses (5) from fittings (6) | Collect escaping coolant with a suitable container and seal openings of fittings (6) with suitable plugs. | |
7 | Detach cable tie (17) and unscrew concealed nut | ||
8 | Remove cross member under instrument panel | ||
9 | Detach electrical wiring harnesses (7) from retaining clips in firewall area | ||
10 | Remove defroster outlet (15) | ||
11.1 | Mark electrical connector (12) | For vehicles with code (I77) Manual air conditioning | |
Risk of being mixed up with electrical connector of blend air flap actuator motor. | |||
12 | Separate electrical connectors (8, 9, 12) | Depending on the equipment variant used the connector (12) is connected to the blend air flap actuator or clipped onto the air conditioner housing (10). | |
13.1 | Disconnect wiring harness from PTC heater booster | Engine 639.9: | |
14 | Remove bracket (13) on air conditioner housing (10) and detach electrical connector underneath | ||
15 | Disconnect electrical connector (14) | ||
16 | Remove air conditioner housing (10) and air recirculation unit (11) at firewall | ||
17 | Remove retaining clips of electrical wiring harnesses on air conditioner housing (10) and on the air recirculation unit (11) | ||
18 | Remove air recirculation unit (11) from air conditioner housing (10) | ||
19 | Remove air conditioner housing (10) | ||
20.1 | Remove blower motor, blend air flap actuator, blower motor series resistor group and evaporator sensor | When replacing the air conditioner housing (10). | |
21.1 | Remove PTC heater booster | When replacing the air conditioner housing (10) with engine 639.9. | |
22 | Install in the reverse order |
Air conditioning system
Documente menționate
- ah8330n000301a Indicaţii pentru manipularea refrigerentului R134a
- ah8330n000401a Comportament dacă instalaţia de climatizare este avariată respectiv neetanşă
- ah8330n000501a Protejarea circuitului şi componentelor instalaţiei de climatizare împotriva umidităţii la lucrările de reparaţie
- ar2000p1142ff
- ar2000p1142fg
- ar6810p1120ff
- ar8325p1402ff
- ar8330p1760ff
- ar8370p800001ff
- as8300z000101a Pericol de explozie datorită lucrărilor de lipire sau sudură la instalaţia de climatizare oprită. Pericol de otrăvire prin inhalarea de vapori de refrigerent supraîncălziţi. Pericol de rănire prin contactul pielii şi ochilor cu