S20.10-3001-06
1 Bolt
2 Coolant hose of expansion reservoir
3 Cap
4 Coolant hose of radiator
5 Coolant thermostat
6 Seal
7 Coolant thermostat housing
8 Lifting eye
| Removing, installing | ||
1 | Remove air cleaner housing | ||
Danger! | Risk of injury to skin and eyes from scalding from hot coolant which splashes out. Risk of poisoning from swallowing coolant. | Do not open the cooling system unless the coolant temperature is below 90 °C. Open cap slowly and allow the pressure to release. Do not pour coolant into containers for drinks. Wear protective gloves, protective clothes, and eye protection. | |
2 | Drain coolant | ||
3 | Unclip cable strap (arrow) from the lifting eye (8) | ||
4 | Detach coolant hoses (2, 4) at the cap (3) | | |
5 | Take off cap (3) with coolant thermostat (5) | | |
6 | Install in the reverse order | ||
7 | Inspect cooling system for leaks |
Coolant pump, coolant thermostat