Check charging voltage of alternator

Typ ar · temat 15.40 · wersja 0101 · 2018-12-17

Dotyczy: Model 470, 471

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 1 Silnik › 15 Instalacja elektryczna silnika › 15.40 Alternator — Seria 470 · Seria 471

EinPAS 25 Instalacja elektryczna/sieć wymiany danych/wielofunkcyjne › 25.20 Sieć pojazdu › 25.20.30 Alternator — Seria 470 · Seria 471

AR15.40-S-5013P

Check charging voltage of alternator

18.10.2018

Model

470, 471

Check charging voltage of alternator

Connection scheme

1

Multimeter

2

On-board electrical system battery

3

Alternator

4

Starter

5

On-board electrical system battery ground point

S15.40-4550-06

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Check

1

Check on-board electrical system battery (2).

AR54.10-S-1129P

2

Fulfill preconditions for alternator test.

AR15.40-S-5009P

3

Attach multimeter (1) to on-board electrical system battery (2) according to connection scheme.

4

Start engine.

5

Check the charge indicator while at an idle and with increasing engine speed (up to 3,000 rpm).

In case of correct charging voltage, no fault message is shown in the display on the instrument cluster.

6

Check charging voltage.

Only apply load to on-board electrical system battery (2) through corresponding permanent consumers (e.g. lighting). Remove transitional resistances at electrical connections of charging system.

In case of charging voltage < 13.0 V

Check diodes of alternator (3).


AR15.40-S-9301-02E

In case of charging voltage > 14.5 V

Replace alternator (3).


Model 470, 471 with engine 699

AR15.40-S-5032PD


Model 470 with engine 200

AR15.40-S-5032PB


Model 470, 471 with engine 642

AR15.40-S-5032PS

7

Switch off engine.

8

Remove multimeter (1).