1 | Bracket |
A | Range |
D62.30-0014-05
| Remove | ||
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
Topical note | Notes on performing repair, body work and welding on vehicles with airbags and RTE units | ||
Topical note | General information on body repair | ||
1 | Remove signal horn | ||
2 | Remove front bumper | ||
3 | Remove other detachable parts in repair area | ||
4 | Cover all detachable parts that remain in repair area | ||
5 | Expose weld seams in area A and grind off | ||
6 | Remove bracket (1) | Grind off connecting plates and coat with zinc dust paint | |
Zinc dust paint suitable for spot welding | |||
| Install | ||
7 | Grind off bracket (1) in welding area on both sides and coat with zinc dust paint | Zinc dust paint suitable for spot welding | |
8 | Position bracket (1) as per dimension data from drawing and align parallel to panel edge of crossmember (arrow) | ||
Danger | The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from inhaling welding gases | Use insulating mats. Wear protective clothing, safety glasses and a protective mask. Remove highly inflammable materials from the hazard area. Use air extraction system. | |
9 | Weld bracket (1) onto the body | ||
Topical note | Measures for preventing damage to vehicles or components when performing electric welding work | ||
General notes on welding | |||
10 | Vacuum out hollow cavities | | |
11 | Clean areas repaired and priming with MB primer filler | ||
12 | Supplement standard underfloor protection with MB permanent underbody sealant | ||
13 | Paint repair area adjacent surfaces | ||
14 | Install horn | ||
15 | Install front bumper | ||
16 | Install other detachable parts in repair area |
참조 문서
- ah0000n000501a 전기 용접 작업 시 차량 또는 부품 손상 방지 조치
- ah6000n000101a 차체 정비 관련 일반 지침
- ah6000n000501a 일반 용접 지침
- ah9100p000201m 에어백 유닛 또는 안전벨트 텐셔너 유닛이 장착된 차량에서의 정비 작업, 차체 작업, 용접 작업 실행에 관한 지침
- ar8820d2000b
- as0000z000701a 전기 용접 시 고전압으로 인한 사망 위험 인화성 물질이 있는 영역에서 실행하는 용접 작업에 의한 폭발 위험 용접 시 발생하는 불티 및 자외선으로 인한 상해 위험 용접 증기 흡입�
- as9100z000101d 에어백 유닛 혹은 안전벨트 텐셔너 유닛의 점검 작업 또는 정비 작업 중 상해 위험