ar1440b2025a

Check pneumatic working pressure at exhaust aftertreatment system metering device

유형 ar · 주제 14.40 · 버전 0201 · 2019-12-14

적용 대상: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2 Engine 926.9 in model 368, 382.17/18, 384.0

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 1 엔진 › 14 배기 매니폴드, 엔진 브레이크, 배기가스 정화장치 › 14.40 배기가스 후처리, AdBlue — 시리즈 368 · 시리즈 382 (모델 17*, 18*) · 시리즈 384 (모델 0**, 2**) · 시리즈 685 (모델 282, 284, 289, 290) · 시리즈 979 (모델 2**)

EinPAS 15 엔진 › 15.40 배기 시스템/배기가스 후처리 시스템 › 15.40.51 펌프/정량기/노즐 — 시리즈 368 · 시리즈 382 (모델 17*, 18*) · 시리즈 384 (모델 0**, 2**) · 시리즈 685 (모델 282, 284, 289, 290) · 시리즈 979 (모델 2**)

엔진/변속기에도 적용: 924 9**, 926 9**

AR14.40-B-2025A

Check pneumatic working pressure at exhaust aftertreatment system metering device

28.11.2019

Engine

924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2

Engine

926.9 in model 368, 382.17/18, 384.0

Check pneumatic working pressure at exhaust aftertreatment system metering      
	device

1

Pressure Gauge

2

Metering hose

3

Metering unit

4

Test connection

W14.40-1476-12

Remove/install

Warning

Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue

Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system.

AS14.40-Z-0001-01A

1

Turn off ignition

Notes on use, material properties and handling of AdBlue®

AH14.40-N-0001-01A

2

Open the engine access cover

3

Install the test connection (4) in the metering unit pressure inlet (3)

Retrofit test connection on compressed air inlet of metering device
.

AR14.40-B-2042A

Only whether a test connection (4) is not installed yet.

The test connection (4) can be kept in the vehicle after the test.

4

Connect the metering hose (2) in the pressure gauge (1), and in the test connection (4)

Pressure gauge

*360589002104

Measuring hose

*360589002102

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

5

Start the engine

Let the engine running until working pressure is built up in the compressed air reservoir.

6

Check the effective pressure with the engine running

After engine shutdown, the dosing unit should be cleaned with compressed air to prevent contamination.

.Nominal operating pressure value in the dosage unit compressed air inlet

*BE14.40-B-1002-02A

7

Disconnect the metering hose (2) in the pressure gauge (1), and in the test connection (4)

The test connection (4) can be kept in the vehicle after the test.

8

Close the engine access cover

Exhaust gas after-treatment

Number

Designation

Engine 924.9, 926.9 with Code MS5

BE14.40-B-1002-02A

Nominal operating pressure value in the dosage unit compressed air inlet

bar

5,5

Check pneumatic working pressure at exhaust aftertreatment system metering      
	device
Check pneumatic working pressure at exhaust aftertreatment system metering      
	device

360 589 00 21 02

Measuring hose

360 589 00 21 04

Pressure gauge

참조 문서