AP83.30-M-8312A | Air conditioning: check refrigerant level | 28.6.04 |
MODEL 904.663
Minibus Sprinter Classic,
with roof air conditioning, Sütrak AC 111
MODEL 904.663
Minibus Sprinter low floor,
with roof air conditioning, Sütrak AC 111
MODEL 904.663
Minibus Sprinter Tourist,
with roof air conditioning, Sütrak AC 111
MODEL 905.613
Minibus Sprinter Classic 6 t,
with roof air conditioning, Sütrak AC 111
MODEL 905.613
Minibus Sprinter low floor 6 t,
with roof air conditioning, Sütrak AC 111
M83.50-0005-05
1 Inspection glass
| Check | ||
Danger | Risk of accident Due to the vehicle starting off of its own accord when the engine is running. Risk of injury from crushing and burns when intervening during the starting procedure or on the running engine | Secure the vehicle to prevent it from starting off of its own accord. | |
1 | Start engine | A coolant temperature of min. 50 °C must be guaranteed. | |
2 | Switch on and adjust max. cooling capacity at the temperature control switch | See air conditioning operator's manual. | |
3 | Remove air filter | ||
4 | Allow engine to run at approx. 1500 rpm | ||
5 | Check refrigerant level in inspection glass (1) after approx 10 minutes | The air conditioning is correctly filled when the refrigerant is visible in the inspection glass (1) without any bubbles. If a lot of bubbles form: Check air conditioning circuit for leaks | |
| |||
6 | Switch off air conditioning and switch off engine | ||
7 | Install air filter |