si2000w0007a

Service Information: Coolant composition

Type si · topic 20.00 · version 0100 · 2017-05-11

Applies to: Model 963, 964

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.00 General — Series 963 · Series 964

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.5 Coolant circuit, complete — Series 963 · Series 964

EinPAS 45 Data/information › 45.20 Information/measures › 45.20.20 Service information — Series 963 · Series 964

SI20.00-W-0007A

Service Information: Coolant composition

20.04.2017

Model

963, 964

Please remember that the correct coolant composition must always be strictly observed.

To ensure optimum heat dissipation and corrosion protection, an anticorrosion/antifreeze concentration of 50 % must be set. This concentration guarantees antifreeze protection down to approx. -37 °C. Higher concentrations, up to max. 55 %, are only useful at even lower ambient temperatures and guarantee antifreeze protection down to approx. -45 °C.

With the correct coolant composition, the antifreeze protection should therefore be between -37 °C and -45 °C.

Anticorrosion/antifreeze concentrations lower than 50 % are not to be used because in this case the silicate content of the coolant is too low.
An inadequate silicate content reduces the anti-corrosion protection considerably and can result in damage to components of the engine cooling system or to the engine.

Anticorrosion/antifreeze concentrations of more than 55 % are not to be used as the maximum antifreeze protection is already reached at this concentration.
An even higher concentration reduces the anti-freeze protection and impairs heat dissipation. Reduced heat dissipation can result in damage to components of the engine cooling system and to the engine.