Refrigerant circuit function

Type gf · topic 83.40 · version 0102 · 2000-03-16

Applies to: MODEL 638.094 /194 /294 with CODE (H06) Air conditioning

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 638 (models 094, 194, 294)

GF83.40-S-2001A

Refrigerant circuit function

19.8.98

MODEL 638.094 /194 /294 with CODE (H06) Air conditioning

Refrigerant circuit function

S83.30-2537-09

Air conditioning plan

1 Refrigerant compressor

2 Condenser

3 Fluid reservoir with dryer

4 Expansion valve

5 Evaporator

6 Heater blower

A20 Air conditioning pushbutton control module

A20b34 Interior temperature sensor

A52 Engine 104.900 control module

A53 CDI control module

B61 Refrigerant fluid reservoir pressure sensor

B77 High/low pressure switch
(engine 111.950 and 111.980)

M34 Radiator blower

P11 Diagnosis socket

P15 Instrument cluster

Y37 Cycle valve

A High pressure (gaseous)

B High pressure (liquid)

C Low pressure (liquid)

D Low pressure (gaseous)

A61 ME control module

A80 Pulsed radiator module
(engine 104.900)

B21 Climate control pressure switch (engine 111.950 and 111.980)

B28 Air outlet temperature sensor

B29 Evaporator temperature sensor

B34 Interior temperature sensor

B37 Ambient temperature sensor

B56 Condensor refrigerant pressure sensor (engine 104.900)

B60 Refrigerant temperature sensor

The refrigerant circuit can be divided into two systems, the high pressure system and the low pressure system.

High pressure system

When the refrigerant has cooled the air in the evaporator, it is led to the refrigerant compressor. The gaseous refrigerant is compressed again and heats up as a result.

The refrigerant is subsequently sent to the condenser. This is where the energy added in the compressor and the heat generated in the evaporator is given off into the surrounding area. This cools the refrigerant, which then liquefies.

In order to keep the refrigerant free of contamination, it is

filtered through a molecular filter between the condenser and the expansion valve and air bubbles are removed.

Low pressure system

When the refrigerant compressor is switched on, the fluid that has cooled in the condenser is injected into the evaporator through the expansion valve.

The refrigerant evaporates and thus extracts the evaporation heat that is required to evaporate the refrigerant from the flow of fresh air. This causes the air to cool, and the moisture in the air condenses.

The expanded gas passing through the expansion valve then returns to the refrigerant compressor, where it is compressed again.

Air conditioning pushbutton control module position/task/design

GF83.40-S-2169A

Evaporator temperature sensor position/task/design

GF83.57-S-2114A

Refrigerant pressure sensor position/task/design/function

Only for model 638.294 with engine 104.900

GF83.40-S-2126A

Only for air conditioning refrigerant pressure sensor (B61)

GF83.40-S-2126B

Blower position/task/design/function

GF83.10-S-2102A

Switchover valve position/task/function

GF83.10-S-2155A

Air conditioning pulsed valve position/task/design/function

GF83.40-S-2137A

Refrigerant compressor position/task/design/function

GF83.55-S-2100A

Condenser position/task/design/function

GF83.40-S-2120A

Fluid reservoir position/task/design/function

GF83.40-S-2122A

Evaporator position/task/design/function

GF83.40-S-2121A

Expansion valve position/task/design/function

GF83.40-S-2123A

High/low pressure switch position/task/design/function

Only for model 638 with engine 111.950 and 111.980

GF83.40-S-2134B

Pressure switch position/task/design/function

Only for model 638 with engine 111.950 and 111.980

GF83.40-S-2135B

Pulsed valve position/task/design/function

GF83.40-S-2137A

Referenced documents