GF83.40-P-2000B | Automatic air conditioning pushbutton control module position/function | 11.12.97 |
MODEL 202 up to 31.8.95 with CODE (581a) Air conditioning (Automatic)
P83.40-2020-11
Automatic pushbutton
Recirculated air pushbutton
Defrost pushbutton
EC pushbutton
Rest pushbutton
ON/OFF pushbutton
Warm temperature pushbutton
Cold temperature pushbutton
Air distribution to windshield and middle level pushbutton
Air distribution to middle level pushbutton
Air distribution to windshield, middle level and footwell pushbutton
Air distribution to middle level and footwell pushbutton
Blower pushbutton
N22 Air conditioning (Automatic) (Automatic) A / C pushbutton control module
Function
The control and operating module (N22) permits performance of adjustments required by the driver, such as:
Automatic air distribution and blower speed by pressing the pushbutton
Passenger compartment temperature selection by pressing the warm/cold pushbuttons ,
Manual air quantity by pressing the pushbutton or blower levels (2 to 4)
Manual air distribution by pressing the pushbuttons , , and
Recirculated air by pressing the pushbutton
Activation of residual engine heat recirculation, with ignition off, by pressing the
pushbutton
Switching off cooling by pressing the pushbutton
Defrosting function by pressing the pushbutton
Shutting off the whole system by pressing the pushbutton
The driver will be shown these adjustments by the diodes integrated into the pushbuttons.
Furthermore the electronics integrated into the control and operating (N22) module take over regulation and control of systems, such as:
comparison of the preselected / actual temperatures and adjustment of the passenger compartment temperature
automatic switching from fresh air to recirculated air
automatic air distribution
automatic blower speed
actuation of the refrigerant compressor
actuation of the auxiliary ventilator
The control and operation module (N22) can be diagnosed so that faults arising are stored in a fault memory, which can be read out on-board or with the aid of the Hand-Held Tester.
When changing the control and operating module (N22) a variant coding should be performed with the aid of the Hand-Held Tester.
Blower pushbutton Location/task/function | |||
Air distribution pushbutton Location/task/function | |||
Recirculated air pushbutton Location/task/function | |||
EC pushbutton Location/task/function | |||
Automatic pushbutton Location/task/function | |||
Rest pushbutton Location/task/function | |||
Warm temperature pushbutton Location/task/function | |||
Cold temperature pushbutton Location/task/function | |||
Defrost pushbutton Location/task/function | |||
ON/OFF pushbutton Location/task/function | |||
Display Location/task/function |
Referenced documents
- gf8340p2139a Defroster button, location/purpose/function
- gf8340p2140e ON/OFF button, location/purpose/function
- gf8340p2144e Blower pushbutton, location/purpose/function
- gf8340p2145a Recirculating air pushbutton, position/task/function
- gf8340p2146e EC button, location / task / function
- gf8340p2147e Auto pushbutton, location/purpose/function
- gf8340p2148a REST pushbutton, location/purpose/function
- gf8340p2150a Display, location/purpose/function
- gf8340p2159e Air distribution pushbutton position/task/function
- gf8340p2160a Warm temperature pushbutton, location/purpose/function
- gf8340p2161a Cold temperature pushbutton, location/purpose/function