gf4016g2002b

Increasing tire inflation pressure function

Type gf · topic 40.16 · version 0100 · 1999-07-27

Applies to: MODEL 437.105 /117 /118 with CODE (A30) Tire control system

Where it sits

Function group 2 Chassis › 40 Wheels, chassis alignment check › 40.16 Tire pressure control system — Series 437 (models 105, 117, 118)

GF40.16-G-2002B

Increasing tire inflation pressure function

3.3.99

MODEL 437.105 /117 /118 with CODE (A30) Tire control system

Switch the "Inflate/deflate" switch to inflate, the 3/2-way valve (33.01a) is energized and switches over. The compressed-air line from the 3/2-way valve (33.01a) to the shuttle valve (28.03) and the 2/2-way valves (45.01b) are pressurized. Then select the relevant axle or both axles with the selector switch.

Depending on the position of the selector switch, the 3/2-way valve (33.01b) are actuated electrically and switch over and therefore also open the passage to the 2/2-way valves (45.01b) to the respective axle. The air can now flow into the tires.

The tire pressures at the front and rear axle can be read off on the two pressure gauges (11.01) in the cab.

Shuttle valve, location/task

GF40.16-G-5002A

3/2-way valve, location/task

GF40.16-G-5004A

3/2-way valve, inflate/deflate, location/task

GF40.16-G-5013A

2/2-way valve, location/task

GF40.16-G-5005A

Tire pressure display, location/task

GF40.16-G-5007A

Selector switch, location/task

GF40.16-G-5009A

Inflate/deflate switch, location/task

GF40.16-G-5011A

Referenced documents