gf2000p2210v

Component description for the low temperature cooling system shutoff valve

Type gf · topic 20.00 · version 0101 · 2007-10-30

Applies to: ENGINE 272.985 in MODEL 211.057 /257, 219.357

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.00 General — Series 211 (models 057, 257) · Series 219 (models 357)

Also applies to engines/gearboxes: 272 985

GF20.00-P-2210V

Component description for the low temperature cooling system shutoff valve

23.5.06

ENGINE 272.985 in MODEL 211.057 /257, 219.357

Component description for the low temperature cooling system shutoff valve

P07.70-2100-01

B6/5 Right intake camshaft Hall sensor

B6/7 Right exhaust camshaft Hall sensor

Y49/5 Right intake camshaft solenoid

Y49/7 Right exhaust camshaft solenoid

Y110 Three-disk thermostat valve

Y125 Low temperature cooling system shutoff valve

Location

The low temperature cooling system shutoff valve is located at the front on the engine above the coolant pump.

Component description for the low temperature cooling system shutoff valve

P20.00-2320-01

Y125 Low temperature cooling system shutoff valve

Task

Closing off the low-temperature cooling system at cold start

Temperature control for the low-temperature cooling system when driving.

Design

The low temperature cooling system shutoff valve has an inlet below and two outputs on the side which open and close at the same time .

The coil resistance at room temperature is approx. 12 Ω.

Without actuation the shutoff valve is open.

Function

If the low temperature cooling system shutoff valve is actuated at the ground end by the ME-SFI [ME] control unit it closes the inlet in the low-temperature cooling system.

Actuation takes place under the following operating conditions:

For as cold start the shutoff valve is closed together

with the heating system shutoff valve so that the engine heats up quicker.

Further actuation takes place dependent on the

fuel temperature, the temperature in the ME-SFI [ME] control unit (integral temperature sensor) and the exhaust gas recirculation rate.

The following components are attached on the low-temperature cooling system:

Low temperature radiator

EGR [ARF] actuator motors

Exhaust gas recirculation connecting pipe to intake manifold

ME control unit