Shown on left side of vehicle |
S60.00-4851-06
1 | Nut |
2 | Bracket |
3 | Electrical connector |
4 | Electrical wiring harness |
5 | Plug |
S60.00-A048-06
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
| Remove/install | ||
1 | Remove front-end assembly. | ||
2 | Remove radiator unit. | ||
3 | Remove front crash box. | ||
4 | Remove the fender liner in the right fender. | ||
5 | Remove ground lines. | To do this, remove nut (1). | |
M8 | |||
6 | Remove electrical connector (3) and place outside of the working area. | Do not disconnect the electrical connector (3). | |
7 | Remove electrical wiring harness (4) and place outside of the working area. | ||
8 | Remove holder (2). | For this purpose, remove nuts. | |
9 | Remove grommets (5). | ||
10 | Install in the reverse order. |
Referenced documents
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ah0060n010001a Special instructions for lifting and supporting vehicle
- ar0850s0120f Remove/install radiator unit
- ar6000s0023e Remove/install front end
- ar6210s0001e Remove/install front crashbox
- ar8810s1300e Remove/install fender liner in front fender
- as0000z001001a Risk of death caused by vehicle slipping or toppling off of the lifting platform.
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)