Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Notes on battery | ||
| Check | ||
1 | Connect diagnostic system. | ||
| |||
2 | Check capacity of each high-voltage battery using diagnostic system. | The test is called up in the diagnostic system as follows: | |
If additional tests or work are necessary, | |||
| |||
perform in accordance with the instructions from the diagnostic system. | |||
After obtaining special order. | |||
3 | Disconnect diagnostic system after completing the tests. | ||
|
Referenced documents
- ad0000d200006ts Connect/disconnect diagnostic unit
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ah5410p000101a Notes on battery
- ah5410p000101a
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)