ap4280t4263d

Automatic load-dependent brake - check play and adjustment

Type ap · topic 42.80 · version 0101 · 2007-03-27

Applies to: MODEL 436.330

Where it sits

Function group 2 Chassis › 42 Brakes - hydraulic and mechanical systems › 42.80 Axle-load dependent brake — Series 436 (models 330)

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.15 Service brake/vacuum system › 21.15.5 Brake system, complete — Series 436 (models 330)

AP42.80-T-4263D

Automatic load-dependent brake - check play and adjustment

21.3.07

MODEL 436.330

Automatic load-dependent brake - check play and adjustment

T42.80-0004-11

Diagram for adjusting automatic load-dependent brake system

1 Rear axle

2 Front axle

A Length = 200 mm (operating lever)

B Length = 160 mm (control linkage)

x Rear axle load

y Brake pressure

Automatic load-dependent brake - check play and adjustment

T42.80-0003-01

3 Test connection upstream of ALB controller (uncontrolled)

4 Front axle test connection downstream of ALB controller (controlled)

5 Rear axle test connection downstream of ALB controller (controlled)

Automatic load-dependent brake - check play and adjustment

T42.80-0002-11

6 Control linkage

7 Actuating lever

Check

1

Check that control linkage (6) and operating lever (7) can move easily and that joints are play-free

2

Check length (B) of control linkage (6) and length (A) of operating lever (7).

If necessary, adjust length of control linkage (6) and operating lever (7).

3

Determine rear axle load of vehicle in ready-to-drive condition

*385589052100

4

Pressurize compressed-air system up to cutoff pressure

Before fully depressing the brake pedal each time, the compressed-air system must be filled until the cutoff pressure is reached.

5

Connect pressure gauge to test connection (3)

The uncontrolled brake pressure must be between 8.1 and 8.4 bar.

6

Connect pressure gauge test connections (4, 5)

7

Fully depress brake pedal

For permissible values, see diagram for adjusting automatic load-dependent brake system.
A deviation of 0.4 bar is permissible. If pressure deviates significantly:

Adjust the ALB controller

- subject to separate repair order.

Check/adjust automatic load-dependent brake (ALB)

AR42.80-T-0050U

8

Detach pressure gauge

9

Check brake system for leaks and proper function

Automatic load-dependent brake - check play and adjustment

Test balance

385 589 05 21 00

Referenced documents