1 | Ball joint |
2 | Articulated |
N33.00-0267-01
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
1 | Lift/jack up vehicle | ||
| |||
| Check | ||
2 | Check all containers for coolant, vacuum, oil, grease and brake fluid for leaktightness and damage | If there are leaks or defects: | |
| |||
Subject to separate repair order, seal or replace leaky components. | |||
3 | Check pneumatic and hydraulic equipment for leaks | If components are leaky: | |
| |||
Subject to separate repair order, seal or replace components. | |||
4 | Check to ensure that all covers and paneling are undamaged and properly secured | If covers and panels are damaged or loose: | |
| |||
Subject to separate repair order, secure or replace components. | |||
5 | Check to ensure that boots and dust caps are undamaged and securely seated | If boots and dust caps are damaged or leaky: | |
| |||
Subject to separate repair order, replace damaged components. |
Referenced documents
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ah0060n010001a Special instructions for lifting and supporting vehicle
- ar0060s1000s Lift/jack up vehicle
- as0000z001001a Risk of death caused by vehicle slipping or toppling off of the lifting platform.
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)