Installation kit FMS – Interface Telematik FMS 1.0
Mercedes-Benz do Brasil is making available to fleet customers with Euro 5 buses a telemetry interface that allows the installation of the FMS 1.0 interface for use with aftermarket telemetry service provider equipment.
Available data for this interface refers to the FMS 1.0 standard, i. e. all parameters are in the open protocol J1939.
With the available open parameters J1939 the following data readings will be possible:
RPM Speed, Odometer, % of acceleration, brake signals, temperature signals, fuel consumption, etc.
For more information about the FMS 1.0 reading parameters, please visit http://www.fms-standard.com
Numbers of the available Kit for mounting: A 382 540 46 35 0010 KIT TELEMATIC PLATFORM FMS (Code J56) “valid for aftermarket”
FMS kit composition
Quantity ............................................. Description
........ 1 ................................................ WS Command Module
........ 1 ................................................ PSM Command Module
........ 1 ................................................ Interface Wiring Harness
........ 1 ................................................ Fixing bracket
........ 1 ................................................ Fixing bracket
........ 2 ................................................ Screws
Note: |
Caso o ponto estrela unipolar esteja completo, deverá ser substituído por um ponto estrela duplo de Nº A 027 545 13 26 e os seus respectivos componentes: conector e terminal, conforme a necessidade, para que seja possível conectar as unidades eletrônicas PSM e WS. |
B54.18-0004-01
A - Unipolar Starpoint
B - Double Starpoint
18-way Connector: A 013 545 64 26
Terminal: A 013 545 78 26
Connector positioning of FMS interface wiring harness
See following illustration
B54.18-0005-09
For correct technology connection follow the steps below: |
1. | Locate the 18-way connector X2355 on the FMS interface wiring harness (Fig. C), and connect it to the WS module in position X1. |
B54.18-0009-10
2. | Locate the 18-way connector with PSM identification (X1) on the FMS interface wiring harness FMS (FIG. C), and connect it to the PSM module in position X1. |
B54.18-0010-04
3. | Locate the 15-way connector with PSM identification (X3) on the FMS interface wiring harness (FIG.H), and connect it to the PSM unit in position X3. |
B54.18-0011-04
4. | After correctly locating and connecting all connectors, locate the 9-way connector X2811 on the FMS interface wiring harness (FIG. C), and connect it o the electric central in position X2811. |
B54.18-0012-05
4.1 | If the socket X2811 is occupied as shown in the figure below, perform the following procedure: |
Remove the connector that is connected to the vehicle, and connect it to the connector X2811 (II) of the FMS interface wiring harness (FIG. E) | |
Then connect the connector X2811(I) of the FMS interface wiring harness (FIG.D) to the connector X2811 of the vehicle. |
B54.18-0006-01
B54.18-0007-01
Connection to the Electric Central X2811 | |
5. | - After finishing the installation of the FMS interface wiring harness together with the modules. |
Check the process in order to start fastening the modules. |
B54.18-0008-01
Fastening of the electronic PSM and WS units with supports at the front end of the vehicle body structure. |
B54.18-0013-01
Programming procedures
1- Diagnosis equipment
1.1 Start the Xentry Diagnostics
1.2 Identify the vehicle and start the DAS
1.3 Perform the quick test
1.4 Access the INS command module
2 - Instrument (INS)
2.1 Select "Control unit adaptations".
2.2 Select "Parameterizations".
2.3 Select "Control unit list:
- Parameter: 01 - 24 (For INS 2004).
- Parameter: 01 - 28 (For INS 2010).
- PID 31 (For INS 2014).
Select "PSM parameterizable special module” (11). |
B54.18-0014-05
2.4.2 Select “WS control unit maintenance system” (23). |
B54.18-0015-05
2.5 Change option "INEXISTENT (A) to "EXISTING” (B), For “PSM” module confirm with key "F3". |
B54.18-0016-05
2.6 Change option "INEXISTENT (A) to "INSTALLED AND DIAGNOSABLE” (C), For “WS” module confirm with key "F3". |
B54.18-0017-05
2.7 Return to DAS main screen and update data with key "F5
The instrument panel procedures are followed by the PSM, FR/CPC, and WS procedures below:
3 Special parameterizable module (PSM) – See following pages
3.1 Access "Special parameterizable PSM control unit" (confirm chassis).
3.2 Select "Control unit adaptations".
3.3 Select "Parametrizations".
Emit current safety copy with Star Diagnosis?
YES, save PSM control unit parameters.
3.4 Select "General parameter assemblies".
3.5 Select "Telematik service".
3.6 Select "All parameters".
3.7 Select “Cotel".
3.8 Change the option from "INACTIVE" to "ACTIVE", confirm with the key "F3".
4. Vehicle control module (FR)
4.1 Return to DAS main screen.
4.2 Access "FR" command module.
4.3 Select "Command module adaptations".
4.4 Select "Programming procedures".
4.5 Perform programming, select "CAN ambient".
4.6 Return to DAS main screen and update data with key "F5".
4.7 Eliminate fault codes from electronic units.
WS programming |
Enable consumption | |
1. | Select the option "Fuel consumption” (18) and confirm with the key "F3" |
B54.18-0035-05
2. | Select option “Parameterizations” (D) and confirm with key F3 |
B54.18-0019-05
3. | Select the "Fuel Consumption Measurement" option (1) and confirm with the key F3 |
B54.18-0020-05
4. | Select the option “Fuel Consumption Measurement” and enable the field to “ACTIVE” (E) done that confirm with the key F3 |
B54.18-0021-05
5. | Select the option “Vehicle” (01) and confirm with the key F3 |
B54.18-0035-05
6. | Select the option “Reading in the KM tachograph” (8) and confirm with the key F3 |
B54.18-0023-05
7. | Check option “Tachograph reading KM”, confirm kilometer reading, if correct confirm with key F3, if incorrect, change it and confirm with key F3 |
B54.18-0024-05
8. | Check the option “Reading in the KM tachograph” (8) if the mileage value remains as in the previous screen |
B54.18-0025-05
PSM programming |
9. | Select option “Command module adaptations” (F) and confirm with key "F3" |
B54.18-0026-05
10. | Select option “Parameterizations” (D) and confirm with key F3 |
B54.18-0027-05
11. | Select option “General parameter assembly" (D) and confirm with key F3 |
B54.18-0028-05
12. | Select the option “Telematik Service” (900) and confirm with the key F3 |
B54.18-0029-05
13. | Select the option “All the Parameters” (01) and confirm with the key F3 |
B54.18-0030-05
14. | Select the option “Interface Cotel” (900.520) and confirm with the key F3 |
B54.18-0031-05
15. | Select the option “Interface Cotel” and change the status to “ACTIVATED” (E) then confirm with the key F3 |
B54.18-0032-05
With all foregoing procedures duly concluded, the system will perform perfect telemetry information readings | |
Information on FMS connector pin configuration | |
Pinning FMS 12-Way Connector: | |
1 -KL31 | |
6- CAN-L | |
9- CAN-H | |
10- KL15 | |
12- KL30 |
B54.18-0033-01
Important information: |
In case of a current fault occurrence in the WS control unit, as shown in the illustration,. proceed as follows. |
B54.18-0034-05
When generating current failures in the WS command module as shown in the previous image, access the parameters 13, 14 and 16 to disable the failures mentioned to each group, with that the failures should be cleaned as shown in the following images. |
B54.18-0035-05
Image referring to parameter 13 - Disable option 1 "Aggregate activated" |
B54.18-0036-05
Image referring to parameter 14 - Disable option 1 "Aggregate activated". |
B54.18-0037-05
Image referring to parameter 16 - Disable option 1 "Aggregate activated". |
B54.18-0038-05