gf8370w3032a

"End heater operation by switching off during controlled shut-off phase", function

Type gf · emne 83.70 · version 0102 · 1999-11-08

Gælder for: MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W '

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 950 · Serie 952 · Serie 953 · Serie 954

GF83.70-W-3032A

"End heater operation by switching off during controlled shut-off phase", function

8.11.95

MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W

"End heater operation by switching off during controlled shut-off phase",       
	function

W83.70-0017-09

1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor

V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel

8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel

Function sequence

Heater switched on with timer (1) for auxiliary heater.

Heater in controlled shut-off phase.

Heater switched off manually with timer (1):

-----------------------------------------------------------------------------------------

- The blower for the vehicle heater is switched off.

- The coolant circulation pump (8) is switched off.

All heater components are switched off.

-----------------------------------------------------------------------------------------

Operating state after switching off the heater

After switching off the heater with the timer the following components remain in operation:

Cooling phase with shut-off delay

Combustion air blower = off

Fuel metering pump = off

Coolant circulation pump = running

Blower for vehicle heater = running

Operating state upon completion of cooling phase with shut-off delay

After completing the cooling phase with shut-off delay all heater components are shut off:

Heating operation terminated

Combustion air blower = off

Fuel metering pump = off

Coolant circulation pump = off

Blower for vehicle heater = off

Burner housing
Location/purpose/design

GF83.70-W-4000A

Heat exchanger, location/purpose/design

GF83.70-W-4017A

Auxiliary heater control module, location/purpose

GF83.70-W-4015A

Coolant circulation pump, location/purpose/design

GF83.70-W-4018A

Combustion air blower, location/purpose/design

GF83.70-W-4019A

Glow pin, location/purpose/design

GF83.70-W-4020A

Flame monitor, location/purpose/design

GF83.70-W-4021A

Timer, location/purpose/design

GF83.70-W-4022A

Fuel metering pump, location/purpose/design

GF83.70-W-4023A

Coolant temperature sensor, location/purpose/design

GF83.70-W-4024A

Overheating sensor, location/purpose/design

GF83.70-W-4025A

Henviste dokumenter