GF83.70-W-3031A | "End heater operation by switching off in full or partial load operation", function | 8.11.95 |
MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W
W83.70-0017-09
1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor
V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel
8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel
Function sequence
Heater switched on with timer (1) for auxiliary heater.
Heater operating in full load or partial load range.
The heater is switched off manually with the timer (1). The heater switches to the cooling phase with shut-off delay:
- The fuel supply is interrupted immediately by switching off the fuel metering pump (14).
- The blower for the vehicle heater is switched off.
-----------------------------------------------------------------------------------------
- The combustion air blower (11) continues to run for
210 seconds cooling the combustion chamber and purging any combustion gases.
- The coolant circulation pump (8) is switched off after 210 seconds.
After completion of the cooling phase with shut-off delay all components for the heater are switched off.
-----------------------------------------------------------------------------------------
Operating state after switching off the heater
After switching off the heater with the timer the following components remain in operation:
Cooling phase with shut-off delay
Combustion air blower, low stage = 1850 rpm
Fuel metering pump = off
Coolant circulation pump = running
Blower for vehicle heater = off
Operating state upon completion of cooling phase with shut-off delay
After completing the cooling phase with shut-off delay all heater components are shut off:
Heating operation terminated
Combustion air blower = off
Fuel metering pump = off
Coolant circulation pump = off
Blower for vehicle heater = off
Burner housing | |||
Heat exchanger, location/purpose/design | |||
Auxiliary heater control module, location/purpose | |||
Coolant circulation pump, location/purpose/design | |||
Combustion air blower, location/purpose/design | |||
Glow pin, location/purpose/design | |||
Flame monitor, location/purpose/design | |||
Timer, location/purpose/design | |||
Fuel metering pump, location/purpose/design | |||
Coolant temperature sensor, location/purpose/design | |||
Overheating sensor, location/purpose/design |