gf4920g3003ma

Exhaust temperature sensor upstream of diesel oxidation catalytic converter, component description

Type gf · emne 49.20 · version 0100 · 2018-09-10

Gælder for: Engine 470.9, 471.9, 473.9 in model 800.320 with GATS 2.0

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 49 Udstødningssystem, udstødningsrensning › 49.20 Udstødningsefterbehandling — Serie 470 (modeller 9**) · Serie 471 (modeller 9**) · Serie 800 (modeller 320)

Gælder også for motorer/gearkasser: 473 9**

GF49.20-G-3003MA

Exhaust temperature sensor upstream of diesel oxidation catalytic converter, component description

24.08.2018

Engine

470.9, 471.9, 473.9 in model 800.320

with GATS 2.0

Exhaust temperature sensor upstream of diesel oxidation catalytic converter,    
	component description

Location

1

Exhaust aftertreatment unit

B67

Exhaust temperature sensor upstream of diesel oxidation catalytic converter

W49.20-A001-76

Task

The exhaust gas aftertreatment (ACM) (A60a) control unit records the temperature of the exhaust flow in the entry chamber of the exhaust gas aftertreatment unit (1) via the temperature sensor exhaust gas before diesel oxidation catalytic converter (B67).

Structure

The sensor consists of a stainless steel housing. The housing contains a measuring element, a PTC resistor. PTC stands for "Positive Temperature Coefficient" and means that the electrical resistance increases as the temperature increases.

Function

The exhaust gas flowing by the sensor affects the measuring element in its interior depending on the temperature. To be more precise, its electrical resistance changes. For this change in resistance to be a measurable electrical initial parameter, a constant measurement current flows through the sensor. The voltage drop involved allows the exhaust gas aftertreatment (ACM) control unit (A60a) to infer the resistance value first and thus the associated temperature value.