AR83.70-P-1177C | Check emission level, adjust if necessary | 2.3.95 |
MODEL 129 as of 1.6.97 with CODE (228) Stationary heater
P83.70-0368-06
X11/4 Datalink connector
| Inspecting | ||
Danger! | Risk of explosion from fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
1 | Set vehicle heater unit to "max". | ||
2 | Set air volume switch of the vehicle heater to position "1" | ||
3 | Switch stationary heater on with button on the timer | The heater must run in full load mode for checking the emission level. The coolant temperature should therefore be below 30 oC before starting heater operation | |
4.1 | Checking emission level with gas trace instrument | | |
4.2 | Checking emission level with carbon dioxide tester | | |
4.3 | Check emission value with 4-gas measuring device | | |
5 | Switch off stationary heater with button on the timer | ||
Adjusting | |||
6 | Connect HHT to the data link | ||
7 | Adjust emission value using the HHT | See Diagnosis Manual | |
8 | Repeat the check of emission value |
Thermo Top C heater unit test values
Number | Designation | Model | ||
BE83.70-P-1001-03B | CO2 value in exhaust gas (gasoline) | Wide open throttle operation | Vol.-% | 8.8...9.8 |
Commercially available tools
Number | Designation | |
WH58.30-Z-1008-13A | CO2-testing unit | |
WH58.30-Z-1010-13A | CO2 test tubes, 1 to 20 percent by volume | |
WH58.30-Z-1012-13A | Gas detector | |
WH58.30-Z-1013-13A | Vehicle emissions sensor | |
WH58.30-Z-1019-13A | Hot air sensor |
Workshop equipment
WE58.40-Z-1001-06A | 4-gas tester |
Henviste dokumenter
- ar8370p117701c
- ar8370p117702c
- ar8370p117704c Udstødningsgasværdien kontrolleres med 4-gas måleudstyr
- as8370z000201a Fare for eksplosion på grund af brændstofdampe, fare for forgiftning ved indånding af forbrændingsgas og fare for personskade på grund af forbrændinger, under eller efter at varmesystemet har været i drift.