P20.00-2646-08
1 | Coolant hose | 3 | Coolant hose | |
2 | Radiator | 4 | Oil cooler |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | Notes on coolant | ||
Notes on coolant level | |||
Drain off | |||
1 | Remove cap from engine cooling system expansion reservoir. | ||
2 | Remove lower engine compartment paneling. | ||
3 | Remove coolant hose (1) from radiator (2) and collect escaping coolant in suitable container. | ||
4 | Remove coolant hose (3) from oil cooler (4) and collect escaping coolant in suitable container. | ||
| Install | ||
5 | Attach coolant hose (3) to oil cooler (4). | ||
6 | Attach coolant hose (1) to radiator (2). | ||
7 | Pour in coolant and bleed engine cooling system. | ||
Test pressure for pressure-testing the engine cooling system | |||
Cooling system | |||
Test cap | |||
Cooler vacuum filling device | |||
NTKL Adaption | |||
Electric vacuum pump | |||
Pressure pump | |||
8 | Check engine cooling system for leak tightness. | ||
9 | Install lower engine compartment lining. |
Radiator or expansion reservoir cap |
Number | Designation | Engine 100, 102, 103, 104, 110, 111, 112, 113, 114, 115, 116, 117, 119, 120, 121, 123, 127, 129, 130, 133, 137, 139, 152, 155, 156, 157, 159, 166, 180, 256, 260, 264, 266, 270, 271, 272, 273, 274, 275, 276, 277, 278, 279, 282, 285 | ||
BE20.30-P-1005-01A | Test pressure for pressure-testing the engine cooling system | Overpressure | bar | 1,4 |
Cooling system |
Number | Designation | Engine 264 in model 222.150 | |||
BF20.00-P-1001-06D | Cooling system | Workshop replacement amount | Main circuit | Liter | 12,0 |
Low-temperature circuit | Liter | - | |||
Antifreeze/water | Down to -37°C | % | 50/50 | ||
-38°C and below | % | 50/45 | |||
Specifications for Operating Fluids, sheet | |||||
Specifications for Operating Fluids, sheet | |||||
Specifications for Operating Fluids, sheet | |||||
285 589 01 21 00
NTKL Adaption
210 589 00 91 00
Test cap
124 589 24 21 00
Pressure pump
285 589 02 21 00
Electric vacuum pump
285 589 00 21 00
Cooler vacuum filling device
Henviste dokumenter
- ah2000n208001a Oplysninger om kølervæske
- ah2000p114201cw Oplysninger kølervæskestand
- ar2000p1010lf
- ar2000p114204olc
- ar2020p744101rq
- ar6120p1105lf
- as2000z000101a Risiko for skoldningsskader på hud og øjne pga. sprøjtende, varm kølervæske. Risiko for forgiftning ved indtagelse af kølervæske