gf5430p2020fa

Settings on workshop level, function

Typ gf · téma 54.30 · verze 0100 · 2008-03-04

Platí pro: MODEL 203.7 as of model year 09/Modification Year 08 model refinement package

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.30 Sdružený přístroj, ukazatele, varovná zařízení — Řada 203 (modely 7**)

GF54.30-P-2020FA

Settings on workshop level, function

22.2.08

MODEL 203.7 as of model year 09/Modification Year 08 model refinement package

General function requirements

C. 15R On

Function sequence for workshop level settings in general

The workshop level serves the technician in the workshop for reading out vehicle and service data and provides assistance with carrying out the service.

One can access the workshop levels for the instrument cluster (A1) by pressing the instrument illumination variable resistor (A1r1) in the Output menu three times within t < 2 s.

The display in the multifunction display (A1p13) changes to the workshop level.

------------------------------------------------------------------------------------------

It is possible to scroll between the respective menus and submenus (S110s1) or in various lists via the scroll forward and back button.

The following menus are accessible:

Vehicle data

Dynamometer test mode

ASSYST Plus workshop

------------------------------------------------------------------------------------------

Vehicle data

The following data can be called up in this menu:

- Voltage (in V) and amp draw (in A) in on-board electrical system

- Data from instrument cluster
(e.g. version numbers, software releases)

- Engine data (e.g. engine number)

- Oil data (e.g. oil quantity, temperature)

- Vehicle data (e.g. chassis number)

Roller test mode

Activating the roller dynamometer mode prevents faults being entered in the ESP and BAS control unit (N47-5) during brake tests on the roller dynamometer.

It is possible to switch between the following settings in the roller dynamometer mode submenu using the left multifunction steering wheel button group (S110):

- On

- With circuit 15 OFF

If the workshop menu is exited and the roller test mode was not activated again previously, the roller test mode menu is called up automatically during the next ignition sequence (with circuit 15R On).

ASSYST Plus workshop

The following data can be called up in this menu:

- Service data

- Full service

After a service is performed, the service interval is reset in this menu.

Instrument cluster, component description

A1

GF54.30-P-6000FA

Electronic Stability Program control unit component description

N47-5

GF42.45-P-5119FA

Steering column module, component description

N80

GF54.21-P-6050FA

Multifunction steering wheel, component description

S110, S111

GF82.90-P-4005FA

Odkazované dokumenty