ar8370d1178b

Checking delivery quantity of fuel metering pump

Typ ar · téma 83.70 · verze 0106 · 2006-07-26

Platí pro: MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation B3L-C MODEL 901.36# /37# /46#, 902.36# /37# /46# /47#, 903.36# /37# /46# /47#, 904.36# /46# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation D3L-C

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 901 (modely 06*, 36*, 37*, 46*) · Řada 902 (modely 06*, 07*, 36*, 37*, 46*, 47*) · Řada 903 (modely 06*, 07*, 36*, 37*, 46*, 47*) · Řada 904 (modely 06*, 36*, 46*)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.46 Čerpadlo/zásobník — Řada 901 (modely 06*, 36*, 37*, 46*) · Řada 902 (modely 06*, 07*, 36*, 37*, 46*, 47*) · Řada 903 (modely 06*, 07*, 36*, 37*, 46*, 47*) · Řada 904 (modely 06*, 36*, 46*)

AR83.70-D-1178B

Checking delivery quantity of fuel metering pump

4.11.96

MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation B3L-C

MODEL 901.36# /37# /46#, 902.36# /37# /46# /47#, 903.36# /37# /46# /47#, 904.36# /46# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation D3L-C

Checking delivery quantity of fuel metering pump

D83.70-0019-06

1 Cover
2 Gasket
3 Glow plug cable
4 Control module
5 Measuring point (-) terminal 4 on control module

6 Measuring point (+) terminal 3 on control module

7 Graduate (15 ml)
8 Voltmeter
9 Fuel line
10 Heater

Removal

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Prerequisites/instructions on checking fuel metering pump delivery quantity

AH83.70-N-0002-01A

1

Remove heater

Models 901.06, 902.06/07, 903.06/07, 904.06

AR83.70-D-5302B

Models 901.36/37/46, 902.36/37/46/47, 903.36/37/46/47, 904.36/46 left-hand steering

AR83.70-D-5302E

Models 901.36/37/46, 902.36/37/46/47, 903.36/37/46/47, 904.36/46 right-hand steering

AR83.70-D-5302D

2

Remove cover (1) together with gasket (2)

3

Clean fuel strainer in intake fitting on fuel metering pump

AR83.70-D-5653B

4

Pull fuel line (9) off of heater (10) and insert end of fuel line into graduate (7)

5

Unscrew mounting nut for holding glow plug cable (3) on glow plug

6

Connect voltmeter (8) to control
module (4)

Test clip (6) to measuring point (+) terminal 3 and test clip (5) to measuring point (-), terminal 4.

*WH58.30-Z-1001-09A

Bleeding

7

Switch on heater (10)

Do not allow glow plug cable to touch ground.

8

Wait until blower starts running, then disconnect glow plug cable (3) from glow plug

Do not allow glow plug cable to touch ground.

Fuel begins to flow after approx.
45 seconds.
To bleed fuel line allow heater to run until fuel flows out uniformly without bubbles.

9

Switch off heater (10)

10

Empty graduate and insert end of fuel
line (9) into graduate (7)

11

Attach glow plug cable (3) to glow plug

Measuring

The fuel is switched off automatically after 90 sec. The quantity of fuel supplied within this 90 second period serves as the test value.

12

Switch on heater (10)

Do not allow glow plug cable to touch ground.

13

Wait until blower starts running, then disconnect glow plug cable (3) from glow plug

Do not allow glow plug cable to touch ground.

Fuel begins to flow after approx.
45 seconds.
When measuring hold graduate at height of glow plug to avoid pressure or vacuum in fuel line.

14

As soon as fuel starts to flow, read off voltage on voltmeter

15

Wait until fuel flow is shut off automatically

16

Switch off heater (10)

17

Evaluate delivery quantity from fuel metering pump

If required values are not reached

AR83.70-D-1178-02B

replace fuel metering pump

AR83.70-D-5652D

Installation

18

Disconnect voltmeter (8) from control module (4)

19

Fasten glow plug cable (3) to glow plug with mounting nut

20

Attach fuel line (9) to heater (10)

21

Install cover (1) together with gasket (2)

Check gasket for damage, replace if necessary.

22

Install heater

Models 901.06/07, 902.06/07, 903.06/07, 904.06/07

AR83.70-D-5302B

Models 901.36/37/46/47, 902.36/37/46/47, 903.36/37/46/47, 904.36/37/46/47
left-hand steering

AR83.70-D-5302C

Models 901.36/37/46/47, 902.36/37/46/47, 903.36/37/46/47, 904.36/37/46/47
right-hand steering

AR83.70-D-5302D

Commercially available tools

Number

Designation

WH58.30-Z-1001-09A

Multimeter

Odkazované dokumenty