AR83.30-L-1209A | Performing short check on air conditioning | 24.2.00 |
MODEL 667, 668, 670 with CODE (H03) Air conditioning in front section
L83.30-0002-06
Shown on model 668
1 Suction side testing and filling valve
2 Pressure side testing and filling valve
L83.30-0001-09
3 Temperature measuring device
5 Air conditioning leak detector
4 Pressure switch
| Inspecting | ||
Danger! | Risk of explosion from welding or braizing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant. | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Do not carry out repair work on the circuit of the air conditioning system unless the system is drained. | |
Danger! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury from bruises and burns if you place your hand into the engine when it is started or when it is running. | Secure vehicle to prevent it moving off by itself. | |
1 | Make the required preparations for testing the air conditioning system on the vehicle | in order to make the testing preparations, | |
Set heater control valve to "cold". | |||
Set heating and ventilation system to fresh air mode. | |||
Side nozzles, center nozzles and footwell flaps must be fully open. | |||
2 | Attach suction, treatment and filling device to testing and filling valves (1, 2) | Observe suction, treatment and filling device operating instructions. | |
| |||
3 | Start vehicle engine and allow to run at idle speed | ||
4 | Switch air conditioning on | The idling speed of the engine must increase when the air conditioning is switched on. No idling speed increase: | |
Check engine speed sensor operation. If a problem is found: | |||
Replace engine speed sensor | |||
5 | Set blower rotary switch to maximum blower setting | ||
6 | Read off pressure from high-pressure manometer when switching off the refrigerant compressor | Compare pressure indicated on high-pressure manometer to specified upper switch-off pressure value: | |
If pressure drops below lower switch-off pressure limit, refrigerant compressor must not switch itself on, and must switch itself off if it is operating at the time. | |||
If upper switch-off pressure is not reached: | |||
Check air conditioning circuit for leaks using air conditioning system leak detector (5) and remedy cause of leaks. | |||
Evacuate air conditioning system, leak test | |||
Fill air conditioning system, replenish (gaseous) | |||
Fill air conditioning system (liquid) | |||
If upper switch-off pressure is exceeded: | |||
Remove pressure switch from fluid reservoir (4) | |||
7 | Insert temperature measuring device (1) probe into center nozzle air outlet and check outlet air temperature | Move blower rotary switch to level "1" and check air outlet temperature after approx. 5 mins. After this time the refrigerant compressor must switch on and off occasionally. | |
If the switch-off temperature deviates when the refrigerant compressor switches off: | |||
Check evaporator temperature switch. | |||
If the lower temperature limit or | |||
upper temperature limit of the air outlet is not reached: | |||
Check refrigerant compressor on/off switching mechanism or check refrigerant pressure before and after the refrigerant compressor. | |||
If refrigerant compressor does not switch on: Check fuse in fuse box, replace if necessary and remedy cause. Possible cause may be engine overheating. | |||
| |||
8 | Switch air conditioning off and turn engine off | ||
9 | Switch off suction, treatment and filling device | | |
10 | Remove suction and pressure lines from testing and filling valves (1, 2) |
Air conditioning system pressure switch test values
Number | Designation | Models 667, 668, 670 | |
BE83.30-N-1001-03B | Upper switch-off pressure switch | bar | 26 (2.6) |
BE83.30-N-1002-03B | Lower switch-off pressure switch | bar | 2 (0.2) |
Air conditioning system test values
Number | Designation | Models 667, 668, 670 | |
BE83.30-N-1001-04B | Lower refrigerant compressor switch-off temperature | °C | 1 |
BE83.30-N-1002-04B | Air outlet lower temperature limit | °C | 5 |
BE83.30-N-1003-04B | Air outlet upper temperature limit | °C | 14 |
Commercially available tools
Workshop equipment
WE58.40-Z-1002-22A | Air conditioning service station |
Odkazované dokumenty
- ar8330d120901a
- ar8330l1762a
- ar8330l1767a
- ar8330l1777a
- ar8330l5620a
- as0000z000501a Nebezpečí úrazu při samovolném rozjetí vozidla při běžícím motoru. Nebezpečí poranění pohmožděním a popálením při výkonech prováděných během startování nebo při běžícím motoru
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem