ap8330m8312a

Air conditioning: check refrigerant level

Typ ap · téma 83.30 · verze 0101 · 2006-07-25

Platí pro: MODEL 904.663 Minibus Sprinter Classic, with roof air conditioning, Sütrak AC 111 MODEL 904.663 Minibus Sprinter low floor, with roof air conditioning, Sütrak AC 111 MODEL 904.663 Minibus Sprinter Tourist, with roof air conditioning, Sütrak AC 111 MODEL 905.613 Minibus Sprinter Classic 6 t, with roof air conditioning, Sütrak AC 111 MODEL 905.613 Minibus Sprinter low floor 6 t, with roof air conditioning, Sütrak AC 111'

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.30 Klimatizace — Řada 904 (modely 663) · Řada 905 (modely 613)

EinPAS 39 Topení/větrání/chlazení › 39.15 Klimatizace › 39.15.5 Klimatizace kompletní — Řada 904 (modely 663) · Řada 905 (modely 613)

AP83.30-M-8312A

Air conditioning: check refrigerant level

28.6.04

MODEL 904.663
Minibus Sprinter Classic,
with roof air conditioning, Sütrak AC 111

MODEL 904.663
Minibus Sprinter low floor,
with roof air conditioning, Sütrak AC 111

MODEL 904.663
Minibus Sprinter Tourist,
with roof air conditioning, Sütrak AC 111

MODEL 905.613
Minibus Sprinter Classic 6 t,
with roof air conditioning, Sütrak AC 111

MODEL 905.613
Minibus Sprinter low floor 6 t,
with roof air conditioning, Sütrak AC 111

Air conditioning: check refrigerant level

M83.50-0005-05

1 Inspection glass

Check

Danger

Risk of accident Due to the vehicle starting off of its own accord when the engine is running. Risk of injury from crushing and burns when intervening during the starting procedure or on the running engine

Secure the vehicle to prevent it from starting off of its own accord.
Wear closed and snug-fitting work clothes.
Do not grip hot or rotating parts.

AS00.00-Z-0005-01A

1

Start engine

A coolant temperature of min. 50 °C must be guaranteed.

2

Switch on and adjust max. cooling capacity at the temperature control switch

See air conditioning operator's manual.

3

Remove air filter

AP83.00-M-8330A

4

Allow engine to run at approx. 1500 rpm

5

Check refrigerant level in inspection glass (1) after approx 10 minutes

The air conditioning is correctly filled when the refrigerant is visible in the inspection glass (1) without any bubbles.

If a lot of bubbles form:

Check air conditioning circuit for leaks
- subject to separate repair order.

*WE58.40-Z-1002-20A

6

Switch off air conditioning and switch off engine

7

Install air filter

AP83.00-M-8330A

Workshop equipment

WE58.40-Z-1002-20A

Air conditioning leak detector

Odkazované dokumenty