an8210w2000a

Retrofitting work lamps

Typ an · téma 82.10 · verze 0104 · 2012-02-15

Platí pro: MODEL 950, 952, 953, 954

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 82 Elektrické zařízení, nástavba › 82.10 Vnější osvětlení — Řada 950 · Řada 952 · Řada 953 · Řada 954

EinPAS 30 Osvětlovací soustava › 30.15 Vnější osvětlení › 30.15.3 Dodatečná montáž/přemontování — Řada 950 · Řada 952 · Řada 953 · Řada 954

AN82.10-W-2000A

Retrofitting work lamps

14.2.12

MODEL 950, 952, 953, 954

Retrofitting work lamps

W82.10-0013-09

1 Waistrail wiring harness

2 Ground cable to ground point in electric compartment

3 Cable to base module A7, fuse F5 (circuit 30) PIN X10.18/15

7 Switch panel

8 Switch panel cover

A7 Base module

S30 Work lamp switch

X10 Connector

4 Cable to base module A7, fuse F2 (circuit 58) PIN X10.18/8

5 Cable to cab/chassis distribution box, connector row X5, connector 4, PIN 18/18

6 Right footwell cover

Retrofitting work lamps

W82.10-0014-06

9 Cover for cab/chassis distribution box

10 Bracket

11 Work lamp wiring harness (shop-made)

E22 Work lamp

Installation

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect ground lead from battery

Ensure that ground lead cannot unintentionally come into contact with negative pole on battery.

Notes on battery

All models

AH54.10-P-0001-01A

2

Remove cover on switch panel (8)

3

Remove switch panel (7) and pivot down

4

Install work lamp switch (S30)

Install in middle of middle row of switches.

5

Remove footwell cover (6)

6

Open electric compartment and release equipment carrier with base module (A7) and swing down

7

Disconnect connector (X10)

8

Remove cover on cab/chassis distribution box (9) and detach cab/chassis distribution box

9

Retrofit waistrail wiring harness (1)

AN82.10-W-2000-01A

Base module wiring diagram

PE54.21-W-2400B

10

Retrofit work lamp (E22) with bracket (10) on cab mount cross member

AN82.10-W-2000-02A

11

Retrofit work lamp wiring harness (11)

Shop-made

AN82.10-W-2000-03A

Base module wiring diagram

PE54.21-W-2400B

12

Install cover on cab/chassis distribution box (9)

13

Install equipment carrier with base module (A7) and close electric compartment

14

Install footwell cover (6)

15

Install switch panel (7) and cover on switch panel (8)

16

Reconnect ground lead to battery

17

Check for proper function

Odkazované dokumenty