W82.10-0013-09
1 Waistrail wiring harness
2 Ground cable to ground point in electric compartment
3 Cable to base module A7, fuse F5 (circuit 30) PIN X10.18/15
7 Switch panel
8 Switch panel cover
A7 Base module
S30 Work lamp switch
X10 Connector
4 Cable to base module A7, fuse F2 (circuit 58) PIN X10.18/8
5 Cable to cab/chassis distribution box, connector row X5, connector 4, PIN 18/18
6 Right footwell cover
W82.10-0014-06
9 Cover for cab/chassis distribution box
10 Bracket
11 Work lamp wiring harness (shop-made)
E22 Work lamp
| Installation | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect ground lead from battery | Ensure that ground lead cannot unintentionally come into contact with negative pole on battery. | |
| Notes on battery | All models | |
2 | Remove cover on switch panel (8) | ||
3 | Remove switch panel (7) and pivot down | ||
4 | Install work lamp switch (S30) | Install in middle of middle row of switches. | |
5 | Remove footwell cover (6) | ||
6 | Open electric compartment and release equipment carrier with base module (A7) and swing down | ||
7 | Disconnect connector (X10) | ||
8 | Remove cover on cab/chassis distribution box (9) and detach cab/chassis distribution box | ||
9 | Retrofit waistrail wiring harness (1) | ||
Base module wiring diagram | |||
10 | Retrofit work lamp (E22) with bracket (10) on cab mount cross member | ||
11 | Retrofit work lamp wiring harness (11) | Shop-made | |
Base module wiring diagram | |||
12 | Install cover on cab/chassis distribution box (9) | ||
13 | Install equipment carrier with base module (A7) and close electric compartment | ||
14 | Install footwell cover (6) | ||
15 | Install switch panel (7) and cover on switch panel (8) | ||
16 | Reconnect ground lead to battery | ||
17 | Check for proper function |
Referenced documents
- ah5410p000101a Notes on battery
- ah5410p000101a
- an8210w200001a Retrofitting waistrail wiring harness
- an8210w200002a Retrofitting work lamps to cross member of cab mounting
- an8210w200003a Retrofitting wiring harness of work lamps
- as5410z000101a Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of