Nhóm chức năng 3 Body › 83 Climate control › 83.55 A/C compressor — Dòng 374 (mẫu 6**) · Dòng 375 · Dòng 930 · Dòng 932 · Dòng 933 · Dòng 934 · Dòng 940 · Dòng 942 · Dòng 943 · Dòng 944 · Dòng 949 · Dòng 950 · Dòng 952 · Dòng 953 · Dòng 954 · Dòng 957 · Dòng 958 · Dòng 959 · Dòng 963 · Dòng 964 · Dòng 970 · Dòng 972 · Dòng 974 · Dòng 975 · Dòng 976

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.1 Basic information — Dòng 374 (mẫu 6**) · Dòng 375 · Dòng 930 · Dòng 932 · Dòng 933 · Dòng 934 · Dòng 940 · Dòng 942 · Dòng 943 · Dòng 944 · Dòng 949 · Dòng 950 · Dòng 952 · Dòng 953 · Dòng 954 · Dòng 957 · Dòng 958 · Dòng 959 · Dòng 963 · Dòng 964 · Dòng 970 · Dòng 972 · Dòng 974 · Dòng 975 · Dòng 976

AR83.55-W-5250A

Correct oil level in air conditioning system when replacing AC compressor

03.12.2019

Model

374.6, 375, 930, 932, 933, 934, 940, 942, 943, 944, 949, 950, 952, 953, 954, 957, 958, 959, 963, 964, 970, 972, 974, 975, 976

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

Draining

1

Drain new refrigerant compressor.

To do so, drain compressor oil via the openings for the low pressure and high pressure line. Dispose of drained compressor oil properly and in an environmentally friendly manner.

2

Drain removed refrigerant compressor.

Drain compressor oil via openings for low-pressure and high-pressure line and collect with a suitable measuring cup.
Dispose of drained compressor oil properly and in an environmentally friendly manner.

Measure

3

Measure drained oil filling capacity of removed refrigerant compressor.

Filling

4

Fill new refrigerant compressor.

When doing so, fill in the same quantity of compressor oil that has been measured on the removed refrigerant compressor. Always use new compressor oil.