gf0705p2000a

Quantity control valve, basic function

ประเภท gf · หัวข้อ 07.05 · เวอร์ชัน 0102 · 2020-07-23

ใช้กับ: Engine all (CAR)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 07 Mixture formation › 07.05 Valves — ซีรีส์ 900 (รุ่น 9**) · ซีรีส์ 902 (รุ่น 9**) · ซีรีส์ 904 (รุ่น 918, 919, 924, 925, 938, 943, 957) · ซีรีส์ 906 (รุ่น 917, 918, 924, 953)

ใช้กับเครื่องยนต์/เกียร์ด้วย: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

GF07.05-P-2000A

Quantity control valve, basic function

09.07.2020

Engine

all (CAR)

Quantity control valve, basic function

P07.02-A011-79

Example illustration

1

High-pressure fuel pump

2

Quantity control valve

Overview

This document contains information on:

General

Function

General

The quantity control valve has the following tasks:

Closed-loop control of the fuel inflow to the pump elements of the high-pressure fuel pump

Interruption of the fuel supply to the pump elements of the high-pressure fuel pump when the engine is switched off

Closed-loop control of the fuel pressure in combination with the pressure regulating valve, fuel pressure sensor and combustion engine control unit

The quantity control valve is installed in the high-pressure fuel pump.

Function

The fuel delivered by the fuel pump enters the high-pressure fuel pump flange. The fuel is fed further to the quantity control valve and fuel overpressure valve.

On the basis of the signal from the combustion engine control unit, the quantity control valve regulates the fuel quantity supplied to the pump elements via an annular passage.

The quantity control valve is actuated by the combustion engine control unit with a pulse width modulated signal. In a deenergized condition, the quantity control valve is open.