AR91.60-P-0611-05A | Deployment of airbag units when no deployment device is present | ||
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461 as of 1.4.94, 463 Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Model 202 up to 30.6.93 Store airbag unit with deployment face up, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13). | |
| Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | ||
| Ignition cable for firing airbag and seat belt tensioner units | ||
| Notes on disposing of airbag and emergency tensioning retractor units |
Use of self-fabricated ignition cable
1 Fabricate ignition cable with a length of at least 10 m with pressure switch.
2 Plug the 2-pin plug connector into the corresponding airbag unit.
3 Connect ignition cable to battery.
4 Press both pressure switches at the same time.
5 For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 2 to 4 after plugging the ignition cable into the second squib.
Maintain a safe distance of 10 meters.