AR91.60-P-0611-02A | Deployment of removed airbag units | ||
Danger! | Risk of injury. Injuries may result when performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect the power supply. | |
Danger! | Risk of injury. Injuries may result when performing testing or repair work on airbag or emergency tensioning retractor units. | Models 124, 129 up to 30.6.93, 140, 202 up to 30.6.93 Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13). | |
| Notes on controlled deployment of airbag, side airbag and emergency tensioning retractor units | Models 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461, 463 | |
| Notes on disposal of airbags and emergency tensioning retractors | All models |
P91.60-0219-01
2 Pressure switch, battery control
3 Pressure switch, deployment
4 Rotary switch
5 Deployment indicator light
7 Plug connector, adapter cable
8 2-pin plug connector
Using the deployment device
1 Plug the 2-pin plug connector (8) into the unit to be scrapped.
2 Dial the rotary switch (4) to position "1".
3 Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.
4 For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 1 through 3 after plugging the ignition cable into the second squib.
Keep a distance of 10 meters for safety.
After a successful deployment, the deployment indicator light (5) flashes.