AR83.70-W-5683A | Removing and installing flame sensor | 1.8.96 |
MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"
MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"
MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP
W83.70-0046-06
1 Upper housing shell
2 Spreading rivet
3 Retaining spring
4 Flame sensor
5 Retainer
6 Retaining clip
7 Exhaust scoop
8 Insulating shell
| Removal, installation | ||
1 | Remove housing shells | ||
2 | Remove insulating shell (8) | Installation: Replace retainer (5). | |
3 | Disconnect flame sensor connector (4) | Installation: When assembling, pay attention to correct cable routing. | |
4 | Remove flame sensor | Pry out retaining spring (3) with pointed tool through opening (arrow). | |
5 | Install in opposite order | ||
Danger! | Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation. | Do not start up or operate stationary heaters, auxiliary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves. | |
6 | Check stationary heater for proper operation |