ar8370s5330b

Removing and installing heater with holder

ประเภท ar · หัวข้อ 83.70 · เวอร์ชัน 0102 · 2010-09-15

ใช้กับ: MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater D5WS or B5WS

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 638 (รุ่น 0**, 1**, 2**)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.30 Heater — ซีรีส์ 638 (รุ่น 0**, 1**, 2**)

AR83.70-S-5330B

Removing and installing heater with holder

7.9.10

MODEL 638.0 /1 /2 as of 13.10.97 with CODE (H12) Hot water auxiliary heater
D5WS or B5WS

Removing and installing heater with holder

S83.70-2503-06

1 Coolant hose
2 Clamp
3 Coolant hose

4 Hot water auxiliary heater

5 Connector

6 Connector

7 Connector

8 Fuel line

9 Holder

10 Clamp

Removal, installation

1

Disconnect ground from battery

Installation: Code radio
Set clock

See

Owner's Manual

AR54.10-S-0005A

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation.

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Danger of severe burns to skin and eyes from hot coolant spewing out. Coolant is toxic when swallowed

Open cooling system only when coolant temperature is below 90 °C. Open cover slowly and reduce pressure. Do not fill beverage containers with coolant. Wear protective gloves, protective clothing and protective goggles.

AS20.00-Z-0001-01A

Danger!

Fuel vapors present an explosion hazard. Fuel is toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

AS47.00-Z-0001-01A

2

Release pressure in coolant circuit

3

Lower hot water auxiliary heater (4) with holder (9)

AR83.70-S-5330-01B

*BA83.70-N-1005-01A

4

Clamp off coolant lines (1, 3) with clamp (4)

*000589543700

5

Disconnect coolant lines (1, 3) from hot water auxiliary heater (4)

Catch coolant running out in suitable vessel.

Check condition of clamps (2), replace if necessary.

6

Remove fuel line

Installation: Replace hose clamp on fuel line.

Catch fuel running out in suitable vessel.

*000589403700

7

Separate connectors (5, 6, 7)

8

Remove hot water auxiliary heater (4) together with holder (9)

9

Install in opposite order

Danger!

Accident hazard resulting from vehicle starting to move by itself with engine running. Danger of injury resulting from pinching and burning when reaching in during the starting operation or with the engine running.

Secure vehicle against starting to move unintentionally.
Wear closed and tight fitting work clothing.

Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

10

Start engine, bleed cooling and heating system

Allow engine to warm up for approx.
1 minute at alternating speeds. Add coolant continuously up to top mark in coolant expansion reservoir.

11

Shut off engine

12

Check for proper function

AR83.70-S-5302-02A

Stationary heater

Number

Designation

Model
638

BA83.70-N-1005-01A

Holder on floor assembly

Nm

8

Removing and installing heater with holder
Removing and installing heater with holder

000 589 40 37 00

Clamp

Clamp

000 589 54 37 00

เอกสารที่อ้างถึง