ar8370d1178c

Check delivery rate of the fuel metering pump

ประเภท ar · หัวข้อ 83.70 · เวอร์ชัน 0108 · 2010-10-05

ใช้กับ: MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Auxiliary heater (warm water) MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Auxiliary heater (warm water) MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) 10 kW warm water auxiliary heater with timer MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Auxiliary heater (warm water) MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (HZ9)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — ซีรีส์ 901 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 902 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 903 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 904 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 905 (รุ่น 6**)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.46 Pump/container — ซีรีส์ 901 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 902 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 903 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 904 (รุ่น 0**, 3**, 4**, 6**) · ซีรีส์ 905 (รุ่น 6**)

AR83.70-D-1178C

Check delivery rate of the fuel metering pump

28.9.10

MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Auxiliary heater (warm water)

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Auxiliary heater (warm water)

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel

MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) 10 kW warm water auxiliary heater with timer

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Auxiliary heater (warm water)

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (HZ9) Heater booster, diesel

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (H12) Auxiliary heater (warm water)

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HZ9) Heater booster, diesel

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (H12) Auxiliary heater (warm water)

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (HZ9) Heater booster, diesel

Check delivery rate of the fuel metering pump

D83.70-1269-06

1 Fuel metering pump

2 Fuel pipe

3 Measuring hose

4 Measuring glass

5 Battery

6 Multimeter

Removing

Danger!

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel and risk of injury to eyes and skin caused by contact with fuel

No fire, sparks, open flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Preconditions/notes regarding checking the delivery rate of the fuel metering pump

AH83.70-N-0002-01A

1

Remove fuel strainer in fuel metering pump intake connection, clean and then install again

AR83.70-D-5653D

2

Remove fuel line (2) from thrust side of fuel metering pump (1)

If two fuel metering pumps are installed, determine the pump to be checked using the fuel lines.

3

Connect measuring hose (3) to thrust side of fuel metering pump, and insert end of measuring hose into a measuring glass (4).

4

Connect multimeter (6) for monitoring the battery voltage to the battery (5)

To measure the delivery rate, a battery voltage of 11 V to 13 V must be applied.

Bleeding

5

Switch heater unit on

Fuel delivery starts after approx. 40 s. In order to bleed fuel line, allow heater to operate until fuel flows evenly and bubble-free out of measuring hose.

6

Switch heater unit off

7

Drain measuring glass and reinsert end of measuring hose into measuring glass

Measure

8

Switch heater unit on

Fuel delivery starts after approx. 40 s. Hold measuring glass at level of heater during measurement.

9

Wait for fuel delivery to stop

The auxiliary heater control unit stops delivering fuel after approx. 90 s.

10

Switch heater unit off

11

Determine delivery quantity in measuring glass and compare to specified values

If the desired values are not achieved:

*BE83.70-N-1001-04A

Replace fuel metering pump.

AR83.70-D-5652E

Install

12

Detach multimeter (6) from the battery (5)

13

Detach measuring hose from fuel metering pump, and reattach fuel line (2)

Check values for fuel metering pump

Number

Designation

Auxiliary water heater (code H12)
Heater B5W S
up to 27.6.01

Auxiliary water heater (code H12)
Heater D5W S
up to 27.6.01

Auxiliary water heater (code H12)
Heater B5W S
as of 28.6.01

BE83.70-N-1001-04A

Fuel delivery quantity in 90 seconds

min

cm3

10.9

7.5

10.4

max.

cm3

12.1

8.6

12.0

Check values for fuel metering pump

Number

Designation

Auxiliary water heater (code H12)
Heater D5W S
as of 28.6.01

Auxiliary water heater 10 kW (code HZ5) Heater D5W S and D5W Z

Heater booster, diesel (code HZ9) Heater D5W Z

BE83.70-N-1001-04A

Fuel delivery quantity in 90 seconds

min

cm3

7.8

7.8

7.8

max.

cm3

9.0

9.0

9.0

เอกสารที่อ้างถึง