Model | 900 |
with code HH9 (Air conditioner, automatic heater control) | |
Model | 906.633 as of 4/14/14 |
with code HK4 (Rear air conditioning, reinforced) | |
with code ZL3 (National version for Latin America) | |
except code XM0 (Facelift) | |
except code XM5 (Facelift Latin America) | |
Model | 906 |
with code HH7 (Roof-mounted air conditioning system, basic) | |
with code HH9 (Air conditioner, automatic heater control) | |
except code XM0 (Facelift) | |
except code XM5 (Facelift Latin America) | |
Model | 906 |
with code HH9 (Air conditioner, automatic heater control) | |
except code HH7 (Roof-mounted air conditioning system, basic) | |
except code XM0 (Facelift) | |
except code XM5 (Facelift Latin America) |
D83.30-1187-08
1 | Fluid reservoir | 2 | Securing clamp | 3 | Screw |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Drain air conditioning system |
| |
MODEL 900, 906 except CODE HK4 (Heavy-duty rear air conditioning) | |||
2 | Remove front bumper |
| |
Model 900, model 906 without code ZX8 (Dodge brand scope) and without code ZX9 (Freightliner (FTL) brand scope) | |||
3 | Remove condenser blower |
| |
4 | Unscrew bolt (3) | ||
5 | Wet fluid reservoir (1) in area of mounting clamp (2) with lubricant | Lubricant, rubber assembly 1 l | |
6 | Pull fluid reservoir (1) upwards and then forwards until screw/bolt on mounting clamp (2) is accessible | ||
7 | Remove screw/bolt of mounting clamp (2) | ||
8 | Remove fluid reservoir (1) together with mounting clamp (2) | ||
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing rings and moisten with compressor fluid. | |||
9 | Seal openings on condenser with stop plugs | Record plug | |
10 | Detach mounting clamp (2) from fluid reservoir (1) | Installation: Replace fluid reservoir (1). | |
11 | Install in the reverse order |
129 589 00 91 00
Record plug