ar8310s2003p

Remove and install right blending air actuator motor

ประเภท ar · หัวข้อ 83.10 · เวอร์ชัน 0200 · 2018-12-04

ใช้กับ: Model 470, 471 with code HH4 (THERMOTRONIC automatic climate control)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.10 Ventilation — ซีรีส์ 470 · ซีรีส์ 471

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — ซีรีส์ 470 · ซีรีส์ 471

AR83.10-S-2003P

Remove and install right blending air actuator motor

21.11.2018

Model

470, 471

with code HH4 (THERMOTRONIC automatic climate control)

Modification notes

31.10.2018

Operation steps revised, operation step validities added.

Remove and install right blending air actuator motor

S83.10-4555-08

Shown on model 470

1

Electrical connector

4

Spacer

2

Screw

5

Right blending air flap actuator

3

AC housing

Remove and install right blending air actuator motor

Shown on model 471

1

Electrical connector

2

Bolts

3

AC housing

4

Spacer

5

Right blending air flap actuator

6

Actuator gate

7

Guide bolts

8

Quadrant

S83.10-A005-05

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Topical note

Notes on carrying out repair work in the vehicle interior

AH68.00-N-0001-01S

Remove

1

Switch off ignition and store transmitter key outside of transmission range (min. 2  m).

2

Remove glove compartment housing.

AR68.10-S-1400P

3

Remove fuse and relay module from crossmember and move out of working area with attached electric lines.

AR54.15-S-0002P

4

Remove screws (2) and remove right air mixing flap actuator motor (5) from air conditioner housing (3).

When removing the right air mixing flap actuator motor (5), the air mixing flap drops to its end position, which corresponds to the coldest temperature setting.
Ensure that the spacer (4) remains at the air mixing flap.

5

Disconnect electrical connector (1) and remove right air mixing flap actuator motor (5).

Check

6

Twist the air mixing flap at spacer (4) by hand in a clockwise direction up to the end stop and then release.

The air mixing flap must drop to its end position by itself.

If there is sluggishness or damage.

Replace air conditioner housing (3).


AR83.30-S-5200P

Install

7

Connect electrical connector (1) at right air mixing flap actuator motor (5).

8

Switch on ignition.

Model 470
with code HH4 (THERMOTRONIC automatic climate control)

9

Set automatic climate control to manual operation and adjust the temperature on the front passenger side to the lowest value.

Model 470
with code HH4 (THERMOTRONIC automatic climate control)

The blower must be activated.
The right air mixing flap actuator motor (5) moves into the position which corresponds to the end position of the air mixing flap.

10

Align right air mixing flap actuator motor (5) at spacer (4) and position at air conditioner housing (3).

Model 470
with code HH4 (THERMOTRONIC automatic climate control)
Ensure that the spacer (4) is correctly seated.

Model 471
with code HH4 (THERMOTRONIC automatic climate control)
If the spacer (4) has been accidentally pulled off the guide during removal, this has to be pushed on again. When doing so, as shown, ensure the correct installation position (arrow A) relative to the actuator gate (6).
The right air mixing flap actuator motor (5) is positioned via the guide pin (7). When doing so, the sector gear (8) must engage in the right air mixing flap actuator motor (5).

11

Tighten screws (2).

Check

12

Perform function test on right air mixing flap actuator motor (5).

13

Switch off ignition and store transmitter key outside of transmission range (min. 2  m).

Model 470
with code HH4 (THERMOTRONIC automatic climate control)

14

Install fuse and relay module at crossmember.

AR54.15-S-0002P

15

Install glove compartment housing.

AR68.10-S-1400P

เอกสารที่อ้างถึง