ar5410p1129tx

Check condition of battery

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0400 · 2020-01-30

ใช้กับ: Model 211, 219

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 211 · ซีรีส์ 219

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 211 · ซีรีส์ 219

AR54.10-P-1129TX

Check condition of battery

20.01.2020

Model

211, 219

Modification notes

25.04.2007

Check fluid level for service fill level indicator incorporated

Operation step 4.2

10.05.2019

Battery capacity 70 Ah VRLA/AGM

BE54.10-P-1010-01A

Remove

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

1

Remove trunk floor covering from trunk

2

Remove spare wheel cover or spare wheel well trim from luggage compartment

Depending on vehicle equipment.

Check

3

Visual inspection of battery or auxiliary battery for external leakage

If leakage found Replace battery, see:

Remove/install battery
Model 219.3

AR54.10-P-0005TX

Remove/install battery
Model 211.0

AR54.10-P-0005T

Remove/install battery
Model 211.2/6

AR54.10-P-0005TA

Remove/install additional battery
Model 211.0/2/6 up to 5/31/06

AR54.10-P-0007T

Remove/install additional battery
Model 219.3 up to 5/31/06

AR54.10-P-0007TX

4.1

Check fluid level in battery, replenish with distilled water if necessary

Without service fill level indicator, not on absorbent glass mat battery.

4.2

Check fluid level of battery

With service fill level indicator, not on absorbent glass mat battery.

Fluid level indicator via service fill level indicator, if color is white, the acid level is too low: Replace battery, see:

Remove/install battery


Model 219.3

AR54.10-P-0005TX


Model 211.0

AR54.10-P-0005T


Model 211.2/6

AR54.10-P-0005TA

5

Check battery

AR54.10-P-1129-01A

Cold cranking amps as per EN

Commercially available devices/tools
Battery tester/test equipment

Battery capacity 12 Ah

*BE54.10-P-1001-01A

Battery capacity 60 Ah VRLA/AGM

*BE54.10-P-1006-01A

Battery capacity 70 Ah VRLA/AGM

*BE54.10-P-1010-01A

Battery capacity 74 Ah

*BE54.10-P-1011-01A

Battery capacity 90 Ah VRLA

*BE54.10-P-1014-01A

Battery capacity 95 Ah VRLA

*BE54.10-P-1015-01A

Battery capacity 100 Ah

*BE54.10-P-1016-01A

6

Reduce increased voltage after charging process

On a battery that is disconnected from the on-board electrical system and with a "Surface voltage" message in the display of the Midtronics battery tester/test equipment.

AR54.10-P-1129-03A

Check the on-board electrical system battery again after the increased voltage is reduced.

Commercially available devices/tools
Battery tester/test equipment

7

Charge battery

With the test code "Charge and check" on the Midtronics battery tester.

AR54.10-P-1130T

Check the battery again after charging.

Install

8

Install spare wheel cover or spare wheel well trim in trunk

Depending on vehicle equipment.

9

Insert trunk floor cover into trunk and close trunk

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1001-01A

Battery capacity 12 Ah

Cold cranking amps

As per EN

A

170

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1006-01A

Battery capacity 60 Ah VRLA/AGM

Cold cranking amps

As per EN

A

660

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1010-01A

Battery capacity 70 Ah VRLA/AGM

Cold cranking amps

As per EN

A

720

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1011-01A

Battery capacity 74 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

265

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

680

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1014-01A

Battery capacity 90 Ah VRLA

Cold cranking amps

As per EN

A

950

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1015-01A

Battery capacity 95 Ah VRLA

Cold cranking amps

As per EN

A

850

Test and adjustment values for battery

Number

Designation

Model all (4xWD, CAR, smart)

BE54.10-P-1016-01A

Battery capacity 100 Ah

Battery test at 20 °C

Acid density

kg/dm3

1,24

Maximum permissible difference between individual battery cells

kg/dm3

0,04

Load current

A

300

Load time

s

10

Voltage

V

10

Cold cranking amps

As per EN

A

760

เอกสารที่อ้างถึง