1 | Stator |
2 | Rotor |
3 | Adapter |
4 | Actuating cylinder |
W43.40-1115-06
Danger ! | Risk of death for persons with implants caused by work on permanent magnet retarder. Risk of injury caused by burns due to contact with hot rotor. | As a safe distance from the permanent magnet retarder, a minimum distance of 30 cm is to be maintained between the permanent magnet retarder and the body parts of the affected person for a person with implants. | |
| Notes on self-locking nuts and bolts | ||
| Remove/install | ||
1 | Use the right multifunction control lever to set the retarder control to the "0" position | ||
2 | Switch off ignition | ||
3 | Remove soundproofing | ||
4 | Remove permanent magnet retarder | ||
5 | Remove rotor (2) with adapter (3) from stator (1) | ||
6 | Remove actuating cylinder (4) from stator (1) | Only when replacing the stator (1). | |
7 | Install in the reverse order |