1 | Rotor |
2 | Adapter |
3 | Bolts |
4 | Stator |
W43.40-1114-06
Danger ! | Risk of death for persons with implants caused by work on permanent magnet retarder. Risk of injury caused by burns due to contact with hot rotor. | As a safe distance from the permanent magnet retarder, a minimum distance of 30 cm is to be maintained between the permanent magnet retarder and the body parts of the affected person for a person with implants. | |
| Notes on self-locking nuts and bolts | ||
| Remove | ||
1 | Use the right multifunction control lever to set the retarder control to the "0" position | ||
2 | Switch off ignition | ||
3 | Remove soundproofing | ||
4 | Loosen screws/bolts (3) | Do not yet remove bolts (3). | |
5 | Remove permanent magnet retarder | ||
6 | Remove rotor (1) with adapter (2) from stator (4) | ||
7 | Remove bolts (3) and remove rotor (1) from adapter (2) | ||
| Install | ||
8 | Mount rotor (1) to adapter (2) | Do not tighten bolts (3) yet. | |
9 | Position rotor (1) with adapter (2) onto stator (4) | ||
10 | Install permanent magnet retarder | ||
11 | Fully tighten bolts (3) | Bolt, rotor to flange adapter | |
12 | Install soundproofing |