Shown on model 906 |
1 | Vacuum tester |
S43.05-4501-11
| Check | ||
Danger ! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
1 | Connect testing unit to brake booster | MODEL 906 | |
MODEL 909 | |||
Test connection | |||
Vacuum tester | |||
2 | Start engine and read off measured value | MODEL 906 with ENGINE 642 | |
MODEL 906 with ENGINE 272 | |||
Vacuum in hose after engine has been running for 30 seconds | |||
3 | Switch off engine, read off measured value | Switch off the engine and immediately read off the measurement value at the vacuum tester (1). | |
The vacuum is permitted to drop by max. 0.2 bar in 10 min. If there is a vacuum loss of above 0.2 bar replace vacuum line with check valve. | |||
Vacuum in hose after 10 min engine OFF | |||
4 | Disconnect testing unit at brake booster | MODEL 906 | |
MODEL 909 |
201 589 13 21 00
Vacuum tester
168 589 08 63 00
Test connection