AR42.10-W-0050A | Remove/install condensation sensor | 17.4.09 |
MODEL 374, 375, 930, 932, 933, 934, 940, 942, 943, 944, 950, 952, 953, 954, 957, 958, 970, 972, 974, 975, 976
W42.10-1206-05
Condensation sensor (B76) without drain valve
1 Connector
2 Jack
3 O-ring
B76 Condensation sensor
W42.10-1207-05
Condensation sensor (B76) with drain valve
1 Connector
2 Jack
3 O-ring
4 Button (drain valve)
5 Paint protection cap
B76 Condensation sensor
Modification notes
17.1.07 | Remove paint protection cap, added. | Step 2 | |
Reset maintenance system (WS) using Star Diagnosis or via instrument (INS), added. | Step 9 | ||
Picture showing condensation sensor (B76) with drain valve, added. |
| Removing | ||
1 | Depressurize compressed-air system | ||
2 | Remove paint protection cap (5) | Only on condensation sensor (B76) with drain valve. | |
3 | Disconnect connector (1) from jack (2) | ||
4 | Remove condensation sensor (B76) | ||
| Checking | ||
5 | Check condensation sensor (B76) using multimeter | Only in the case of complaint. | |
Condensation sensor (B76) without drain valve | |||
Condensation sensor (B76) with drain valve | |||
Condensation sensor status: "Dry" | |||
Condensation sensor status: "Wet" | |||
| Test adapter | ||
| Install | ||
6 | Install condensation sensor (B76) | If the condensation sensor (B76) is dropped, it must be replaced even if no damage is visible. | |
Inspect O-ring (3), replace if necessary. | |||
| |||
7 | Attach connector (1) to jack (2) | ||
8 | Attach paint protection cap (5) | Only on condensation sensor (B76) with drain valve. | |
9 | Read out fault memory in maintenance system (WS); delete stored faults if necessary | ||
10 | Reset maintenance system (WS) using Star Diagnosis or via instrument (INS) | Only if there was no water in the compressed air system, the condensation sensor (B76) did not detect the appropriate status correctly and was therefore replaced. |
Test and adjustment values for service brake
Number | Designation | Model | Model | ||
BE42.10-N-1017-10B | Condensation sensor status: "Dry" | V | 1.1 to 2 | 1.1 to 2 | |
BE42.10-N-1018-10B | Condensation sensor status: "Wet" | V | 3.1...4 | 3.1...4 | |
Test and adjustment values for service brake
Number | Designation | Model | Model | ||
BE42.10-N-1017-10B | Condensation sensor status: "Dry" | V | 1.1 to 2 | 1.1 to 2 | |
BE42.10-N-1018-10B | Condensation sensor status: "Wet" | V | 3.1...4 | 3.1...4 | |
Test and adjustment values for service brake
Number | Designation | Model | ||
BE42.10-N-1017-10B | Condensation sensor status: "Dry" | V | 1.1 to 2 | |
BE42.10-N-1018-10B | Condensation sensor status: "Wet" | V | 3.1...4 | |
Test and adjustment values for service brake
Number | Designation | Model | Model | ||
BE42.10-N-1017-10B | Condensation sensor status: "Dry" | V | 1.1 to 2 | 1.1 to 2 | |
BE42.10-N-1018-10B | Condensation sensor status: "Wet" | V | 3.1...4 | 3.1...4 | |
Test and adjustment values for service brake
Number | Designation | Model | Model | ||
BE42.10-N-1017-10B | Condensation sensor status: "Dry" | V | 1.1 to 2 | 1.1 to 2 | |
BE42.10-N-1018-10B | Condensation sensor status: "Wet" | V | 3.1...4 | 3.1...4 | |
Condensation sensor
Number | Designation | Model | Model | Model | Model | ||
BA42.60-N-1001-02A | Condensation sensor in compressed air reservoir | M22x1.5 | Nm | 50 | 50 | 50 | 50 |
Condensation sensor