si5410b0041a

Service Information: Battery replacement during term of warranty

Vrsta si · tema 54.10 · različica 0101 · 2020-08-27

Velja za: Model 368 Model 382 Model 384 Model 386 Model 634 Model 688 Model 693 Model 694 Model 695 Model 696 Model 934 Model 938 Model 958, 979

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 2 Podvozje › 54 Električni sistem, oprema in inštrumenti › 54.10 Akumulator, napajanje z napetostjo, napetostni pretvornik — Serija 368 · Serija 382 · Serija 384 · Serija 386 · Serija 634 · Serija 688 · Serija 693 · Serija 694 · Serija 695 · Serija 696 · Serija 934 · Serija 938 · Serija 958 · Serija 979

EinPAS 25 električno omrežje/omrežje/več funkcij › 25.20 električno omrežje › 25.20.20 akumulator — Serija 368 · Serija 382 · Serija 384 · Serija 386 · Serija 634 · Serija 688 · Serija 693 · Serija 694 · Serija 695 · Serija 696 · Serija 934 · Serija 938 · Serija 958 · Serija 979

EinPAS 45 podatki/informacije › 45.20 informacije/ukrepi › 45.20.20 servisne informacije — Serija 368 · Serija 382 · Serija 384 · Serija 386 · Serija 634 · Serija 688 · Serija 693 · Serija 694 · Serija 695 · Serija 696 · Serija 934 · Serija 938 · Serija 958 · Serija 979

SI54.10-B-0041A

Service Information: Battery replacement during term of warranty

21.08.2020

Model

368

Model

382

Model

384

Model

386

Model

634

Model

688

Model

693

Model

694

Model

695

Model

696

Model

934

Model

938

Model

958, 979

Modification notes

12.08.2020

The document SI54.10-B-0017Aon how to proceed with recharging the batteries was indicated.

Indication of the battery recharge procedure.

Vehicles inoperative for long period - important considerations

If the vehicle remains inoperative for a long period (without engine operation), disconnect the battery negative lead;

If the vehicle remains immobilized for more than 30 (thirty) days, it will be necessary to recharge the batteries according to the procedure indicated in SI54.10-B-0017A.

Should it be necessary to move the vehicle, provided the batteries are charged, connect the battery negative lead checking the terminal screw tightening torque which must be 12 Nm +/- 1 Nm;

For vehicles with Proconve P7 motorization (Euro 5) BlueTec 5, before disconnecting the battery ground cable it is necessary to wait 5 (five) minutes after engine shutdown to ensure that the cleaning process of the AdBlue line is carried out. This process is fundamental to avoid the crystallization of the urea contained in the AdBlue, thus avoiding damages in the exhaust gas aftertreatment system.

When running the vehicle engine, observe if the location is appropriate, i.e., that it has good ventilation.

Analysis of batteries and shipping of batteries under guarantee

Before filing a guarantee claim for batteries, a series of checks is necessary in order to detect eventual discrepancies in the power generating system (alternator), of actuation (starter motor) besides the general vehicle electric wiring system.

Check the procedures for assessing the batteries according to information below, SI54.10-B-0017A.

It is important that the Dealer checks the charge condition of the battery when receiving a new vehicle.

No guarantee claims will be accepted of battery failure caused by long storage periods of the chassis/vehicle at the Dealer, transporter or implementer/body builder.

Service Information bulletin: Battery test and inspection

SI54.10-B-0017A