gf8370p3065a

Fault in detecting coolant temperature function

Tip gf · temă 83.70 · versiune 0103 · 2000-07-06

Valabil pentru: MODELS 215, 220 up to 31.5.00 with CODE (228) Stationary heater

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 83 Climatizare › 83.70 Încălzire staţionară, încălzire suplimentară, încălzitor auxiliar — Seria 215 · Seria 220

GF83.70-P-3065A

Fault in detecting coolant temperature function

19.5.98

MODELS 215, 220 up to 31.5.00 with CODE (228) Stationary heater

Fault in detecting coolant temperature function

P83.70-2221-09

1 Burner housing

2 Heat exchanger

3 CAN bus

A6/1 STH radio remote control receiver

N22 AAC pushbutton control module

S46 STH switch

Y23 STH fuel metering pump

A6m1 Circulation pump

A6m2 Combustion air blower

A6n1 STH control module

Functional procedure

1 The heater operates in partial load or full load mode. Combustion is stable.

2 Internal coolant temperature acquisition is continuously monitored by the STH control module (A6n1).

3 The STH control module detects a coolant temperature acquisition malfunction:

The temperature signal has exceeded the temperature acquisition range.

4 The STH control module initializes a malfunction shutoff in order to protect the heater.

5 The STH fuel metering pump (Y23) is switched off, and combustion is interrupted.

6 The STH control module initializes the STH radio remote control receiver (A6/1) with the "Vehicle blower off" signal.

7 The radio remote control receiver reports the end of heater operation to the AAC pushbutton control module (N22) via the CAN bus (3). The pushbutton control module interrupts the initialization of the vehicle blower.

8 Heater disturbance run-on occurs for approx. 120 s.

9 Heater run-on, and therefore malfunction shutoff, are terminated. The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off. The green telltale in the STH switch (S46) is extinguished.

In order to recommission the heater, this must be switched off and on again following the eradication of the trouble source.

Burner housing position/task/structure

GF83.70-P-4000GC

Heat exchanger position/task/structure

GF83.70-P-4001A

Stationary heater/heater booster control module position/task

GF83.70-P-4002A

Recirculation pump position/task

GF83.70-P-4003A

Combustion air blower position/task

GF83.70-P-4004A

Fuel metering pump position/task

GF83.70-P-4008A

Stationary heater radio remote control task/structure

GF83.70-P-4049A

Stationary heater switch position/task

GF83.70-P-4056A

Documente menționate