Pneumatic system equipment, function

Tip gf · temă 80.30 · versiune 0105 · 1999-07-28

Valabil pentru: MODEL 129, 140 as of 1.6.96, 210 / (except 210.081 /281) as of 1.6.96 up to 28.2.97 with CODE (491) USA version MODEL 202 as of 1.8.96 up to 31.5.97 with CODE (491) USA version

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 3 Suprastructură › 80 Închidere centralizată, comandă confort, sisteme de autorizare a pornirii › 80.30 Telecomandă cu IR — Seria 129 · Seria 140 · Seria 202 · Seria 210 (modele 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 282, 283, 606, 610, 616, 617, 663)

EinPAS 29 Sistem autorizare pornire/Sistem de siguranță › 29.16 Blocare/deblocare › 29.16.11 Calculator/Releu — Seria 129 · Seria 140 · Seria 202 · Seria 210 (modele 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 282, 283, 606, 610, 616, 617, 663)

GF80.30-P-4004-01B

Pneumatic system equipment, function

DAS X

Function

Model 129

To unlock, the pneumatic system equipment (PSE) is actuated by the IR DAS control module.

Models 140/202

To unlock, the pneumatic system equipment (PSE) is actuated by the IR DAS control module via a ground signal.

Model 210

To unlock the multi-function control module is actuated by the IR DAS control module. The multi-function control module then sends the signal to the PSE control module via the CAN bus.

The pump motor starts running and supplies pressure. The CL actuators are pressurized. When a pressure of 450 mbar is reached in the system the pump is switched off by the pressure switch. The pressure in the system is then released by the PSE and the unlocking operation is completed.
The locking procedure is accomplished analog to the unlocking operation. However the next time the remote control button is pressed the PSE is also actuated by connecting it through to ground by the second control lead on the IR DAS control module. The direction of rotation for the pump motor is reversed thereby providing the vacuum required to lock.