Shown with engine 780.701 |
1 | Heat exchanger |
S20.00-A000-81
S20.00-A001-78
Shown with engine 780.701 |
1 | Heat exchanger | 5 | Nut | 8 | Refrigerant line | ||
2 | Expansion valve | 6 | Refrigerant line | 9 | Coolant hose lines | ||
3 | Electrical connector | 7 | Nut | 10 | Bolts | ||
4 | Electrical connector |
Shown on removed heat exchanger (1) |
1 | Heat exchanger |
2 | Expansion valve |
S20.00-A002-71
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Engine 780.701 in model 447 | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | Engine 780.701 in model 447 | ||
| Remove/install | ||
1 | Drain refrigerant circuit. |
| |
2 | Drain coolant of high-voltage battery cooling system. |
| |
Engine 780.702 in model 447 | |||
3 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m). | ||
4 | Disconnect electrical connectors (3, 4). | ||
5 | Remove nut (5) of refrigerant line (6). | Nut, refrigerant line to expansion valve for high-voltage battery | |
6 | Remove refrigerant line (6) at expansion valve (2). | ||
| Compressor oils (specification 362.1) | ||
Plug openings. | |||
Installation: Install new sealing ring and coat with compressor oil. | |||
Record plug | |||
7 | Remove nut (7) of refrigerant line (8). | Nut, refrigerant line to expansion valve for high-voltage battery | |
8 | Remove refrigerant line (8) at expansion valve (2). | ||
| Compressor oils (specification 362.1) | ||
Plug openings. | |||
Installation: Install new sealing ring and coat with compressor oil. | |||
Record plug | |||
9 | Remove coolant hose lines (9) at heat exchanger (1). | ||
Collect escaping coolant using suitable vessel. | |||
Set of protective covers | |||
10 | Remove screws (10). | Bolt, heat exchanger of high-voltage battery cooling system to holder | |
11 | Remove heat exchanger (1) with attached expansion valve (2) and pressure and temperature sensor. | The heat exchanger (1) is delivered as a replacement part with expansion valve (2) and pressure and temperature sensor. | |
12 | Install in the reverse order. |
001 589 01 91 00
Set of protective covers
129 589 00 91 00
Record plug
Documente menționate
- ah0000z030001a Indicații generale la autovehicule cu rețea de bord de înaltă tensiune și/sau acumulator litiu-ion și/sau sistem de tracțiune pe gaz, cât și echipament de protecție personală
- ah5400p000101a Indicaţii pentru evitarea defectării componentelor electronice prin descărcare electrostatică
- ah8330n000301a Indicaţii pentru manipularea refrigerentului R134a
- ah8330n000401a Comportament dacă instalaţia de climatizare este avariată respectiv neetanşă
- ah8330n000501a Protejarea circuitului şi componentelor instalaţiei de climatizare împotriva umidităţii la lucrările de reparaţie
- ah8330p000302a Indicaţii pentru manipularea agentului de răcire R1234yf
- ar0850s0021f
- ar0850s0022g
- ar0850s8001f
- ar2020p744101rq Deschidere, închidere cuplă conductă lichid răcire
- as0000z003501a Pericol de moarte în cadrul lucrărilor la componentele şi sistemele cu U >= 30 V tensiune alternativă (CA) respectiv cu U >= 60 V tensiune continuă (CC)
- as2000z000101a Pericol de rănire la piele şi ochi prin opărire cu lichid de răcire fierbinte pulverizat afară. Pericol de otrăvire datorită înghiţirii lichid de răcire.
- as8300z000601a Pericol de intoxicare prin inhalarea vaporilor supraîncălziţi de refrigerent ai unei instalaţii de climatizare umplute cu R134a. Pericol de rănire prin contactul pielii şi ochilor cu refrigerent R134a lichid şi la activităţi într
- as8300z000701a Pericol de incendiu prin aprinderea refrigerentului R1234yf la componente fierbinţi. Pericol de otrăvire prin inhalarea de vapori de refrigerent supraîncălziţi. Pericol de rănire la contactul pielii şi ochilor cu refrigerent
- bb0040p036201a Uleiuri de compresor (specificaţie 362.1)