2 | Tensioning rail |
5 | Top slide rail |
6 | Lower slide rail |
7 | Slide rail pins |
P05.20-2395-12
Caution | Risk of injury to skin and eyes due to handling of engine oil. Risk of poisoning caused by swallowing engine oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove cylinder head cover. | ||
Installation: Only install upper engine cover after the leak test. | |||
2 | Remove upper slide rail (5) from cylinder head cover. | ||
3 | Remove the timing case cover. | When removing the lower slide rail (6). | |
4 | Remove cylinder head. | When removing the lower slide rail (6). | |
5 | Remove lower slide rail (6) from slide rail pins (7). | When removing the lower slide rail (6). | |
| Check | ||
6 | Check tensioning rail (2) for wear and damage. | If there is a problem, | |
| |||
Replace tensioning rail (2). | |||
7 | Check upper slide rail (5) and lower slide rail (6) for wear and damage. | If there is a problem: | |
| |||
Replace upper slide rail (5) and lower slide rail (6). | |||
8 | Install in the reverse order. | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
9 | Perform engine test run. While doing so, check engine for proper operation and leak tightness. | ||
10 | Install upper engine cover. |
Documente menționate
- ah0000p500001a Indicaţii pentru evitarea defecţiunilor din cauza impurităţilor şi corpurilor străine
- ar0120p5014mrm
- ar0130p5800mrm
- ar0140p8000mrm
- ar0510p8510mrm
- as0000z000501a Pericol de accident prin pornirea de pe loc cu motorul aflat în funcţionare. Pericol de rănire prin striviri şi arsuri la manipularea în timpul pornirii motorului sau cu motorul aflat în funcţionare
- as1800z000101a Pericol de rănire a pielii şi ochilor la manipularea uleiului de motor. Pericol de intoxicare prin înghiţire de ulei de motor