P83.30-1074-06
1 Evaporator housing
2 Clamp
3 Clip
4 Stepper motors, connection
P83.30-1078-06
1 Evaporator housing
4 Stepper motors, connection
5 Stepper motors, connection
6 Clip
P83.30-1082-06
7 Clip
8 Air distributor, upper section
9 Evaporator
P83.30-1085-04
10 Screws
11 Expansion valve
| Removing, installing | ||
Danger! | Risk of explosion through welding or soldering operations on closed air conditioning system. Risk of poisoning through inhaling overheated refrigerant vapors. Risk of injury through skin and eye contact with fluid coolant | Do not carry out welding operations on closed air conditioning system or around it. Smoking and naked flame are forbidden. Wear protective glasses and protective gloves, work only in well ventilated areas. Only carry out repair operations on air conditioning circuit with system drained. | |
| Procedure with damaged or leaking air conditioning system | ||
| Protect air conditioning circuit and components from dampness when carrying out repair operations | ||
| Notes for handling refrigerant R134a | ||
1 | Drain air conditioning system (recycling), purge, fill, check for leaks | When evacuating refrigerant, the quantity of compressor oil evacuated must be added again to refrigerant circuit when refilling air conditioning (new oil) | |
2 | Remove evaporator housing (1) | ||
3 | Remove heat exchanger | ||
4 | Detach stepper motors connections (4) | ||
5 | Detach 2 clamps (2) | ||
6 | Detach 4 clips (3) | ||
7 | Detach stepper motors connections (5) | ||
8 | Detach 7 clips (6) | ||
9 | Detach 7 clips (7) | ||
10 | Remove air distributor, upper section (8) | ||
11 | Detach evaporator core (9) | Clean air distributor, lower section | |
Installation: Note oil top-up quantity when replacing evaporator | |||
12 | Unscrew screws (10) | Installation: Tighten screws alternately to avoid jamming | |
| |||
13 | Detach expansion valve (11) | Close off openings (parts kit), | |
14 | Replace fluid reservoir | ||
15 | Install in the reverse order |
Air conditioning
A/C compressor
Documentos referenciados
- ah8330n000301a Indicações para o manuseio com o agente refrigerante R134a
- ah8330n000401a Procedimento em sistemas de ar condicionado danificadas ou com vazamento
- ah8330n000501a Nos trabalhos de reparo em sistemas de ar condicionado proteger o circuito e os componentes em relação à umidade
- ar8325p1100m
- ar8330p5200m
- ar8330p6520m Remover e instalar o reservatório de fluidos
- as8300z000101a Risco de explosão nos trabalhos de solda em sistema de ar condicionado. Risco de envenenamento pela inalação dos vapores superaquecidos do agente refrigerante. Risco de lesão através do contato da pele e dos olhos com o agente refrige