P83.25-0452-06
1 A/C housing
2 Screw
3 Cover
4 Clamp
P83.25-0451-06
5 Retaining clamp
6 Screw
7 Screw
8 Heat exchanger
9 Insert fork
10 Screw
c Heating water flow pipe
d Heating water return pipe
| Remove/install | ||
Danger! | Risk of injury to skin and eyes from scalding with hot coolant which splashes out. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles. Wear protective gloves, protective clothing and eye protection. | |
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant. | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Conduct if air conditioning system is damaged or leaking | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
| Notes on handling refrigerant R134a | All models with R134a refrigerant | |
1 | Drain air conditioning (recycle) | Replenish extracted quantity of compressor oil in the refrigerant circuit (fresh oil) when filling the air conditioning system. Before filling the air conditioning system: | |
Replace receiver/drier | |||
2 | Remove AC housing | ||
3 | Unclip clamps (4) | ||
4 | Unscrew screws (2) | ||
5 | Take off cover (3) | ||
6 | Detach retaining clamps (5) on heating water flow pipe | ||
7 | Remove screws (6) of heating water flow pipe's bracket | ||
8 | Remove screws (7) of heating water flow pipe's guide | ||
9 | Pull out heat exchanger (8) with the heating water pipes | Clean heater housing from inside, if necessary remove escaping coolant. | |
10 | Detach socket yoke (9), remove heating water flow pipe (c) | Fit new O-rings and replace socket yoke. | |
11 | Remove bracket screw (10) and detach heating water flow pipe (d) | Fit new O-rings. | |
12 | Install in the reverse order |
Documentos referenciados
- ah8330n000301a Indicações para o manuseio com o agente refrigerante R134a
- ah8330n000401a Procedimento em sistemas de ar condicionado danificadas ou com vazamento
- ah8330n000501a Nos trabalhos de reparo em sistemas de ar condicionado proteger o circuito e os componentes em relação à umidade
- ar8330p5200m
- ar8330p6520m Remover e instalar o reservatório de fluidos
- as2000z000101a Risco de lesão na pele e olhos provenientes de queimaduras causadas pelo vapor ou líquido de arrefecimento superaquecido. Risco de envenenamento por ingestão do líquido de arrefecimento
- as8300z000101a Risco de explosão nos trabalhos de solda em sistema de ar condicionado. Risco de envenenamento pela inalação dos vapores superaquecidos do agente refrigerante. Risco de lesão através do contato da pele e dos olhos com o agente refrige